Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

48

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0070 # 03 Y:1982 03 1982 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $13,079 $15,000 Implemented
UD0069 # 02 Y:1982 02 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $257 $500 Not Implemented
UD0069 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,154 $272 Not Implemented
GT0146 # 03 Y:1982 03 1982 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,301 $3,296 Not Implemented
GT0146 # 02 Y:1982 02 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,881 $5,192 Not Implemented
GT0146 # 01 Y:1982 01 1982 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,459 $0 Not Implemented
UD0070 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $594 $158 Not Implemented
UD0069 # 03 Y:1982 03 1982 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,195 $3,000 Not Implemented
UD0069 # 04 Y:1982 04 1982 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $2,157 $2,629 Not Implemented
UD0070 # 04 Y:1982 04 1982 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $34,531 $43,000 Not Implemented
UD0070 # 02 Y:1982 02 1982 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $6,051 $10,000 Implemented
UD0062 # 02 Y:1982 02 1982 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,859 $25,000 Not Implemented
UD0062 # 01 Y:1982 01 1982 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $10,658 $1,240 Not Implemented
TN0158 # 01 Y:1982 01 1982 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES $10,490 $1,308 Not Implemented
TN0152 # 01 Y:1982 01 1982 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $11,700 $30,000 Not Implemented
TN0152 # 03 Y:1982 03 1982 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,620 $0 Implemented
TN0152 # 02 Y:1982 02 1982 INSTALL TIMERS AND/OR THERMOSTATS $5,940 $0 Implemented
TN0137 # 04 Y:1982 04 1982 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $131 $0 Not Implemented
TN0137 # 03 Y:1982 03 1982 USE RADIANT HEATER FOR SPOT HEATING $305 $996 Not Implemented
TN0137 # 02 Y:1982 02 1982 INSTALL TIMERS AND/OR THERMOSTATS $500 $510 Not Implemented
TN0137 # 01 Y:1982 01 1982 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $1,517 $1,635 Not Implemented
GT0129 # 04 Y:1982 04 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,387 $872 Not Implemented
GT0129 # 03 Y:1982 03 1982 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,398 $0 Not Implemented
GT0129 # 02 Y:1982 02 1982 COVER OPEN TANKS $55,090 $5,750 Not Implemented
GT0129 # 01 Y:1982 01 1982 RECOVER WASTE HEAT FROM EQUIPMENT $23,148 $15,500 Not Implemented