Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
344
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DS0015 # 06 Y:1994 | 06 | 1994 | INSULATE BARE EQUIPMENT | $50 | $241 | Not Implemented |
DS0015 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,981 | $4,356 | Implemented |
DS0015 # 02 Y:1994 | 02 | 1994 | INSTALL OCCUPANCY SENSORS | $590 | $200 | Implemented |
DS0015 # 03 Y:1994 | 03 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,378 | $744 | Implemented |
DS0015 # 04 Y:1994 | 04 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,343 | $13,182 | Implemented |
DS0015 # 05 Y:1994 | 05 | 1994 | INSULATE BARE EQUIPMENT | $249 | $257 | Not Implemented |
WI0219 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $644 | $782 | Implemented |
WI0219 # 03 Y:1994 | 03 | 1994 | INSTALL OCCUPANCY SENSORS | $744 | $375 | Not Implemented |
WI0219 # 01 Y:1994 | 01 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,622 | $0 | Implemented |
UL0114 # 04 Y:1994 | 04 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,440 | $85 | Implemented |
UL0114 # 03 Y:1994 | 03 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,769 | $2,000 | Not Implemented |
UL0114 # 05 Y:1994 | 05 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $127,600 | $190,000 | Not Implemented |
UL0114 # 02 Y:1994 | 02 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,092 | $4,157 | Not Implemented |
UL0114 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,207 | $5,550 | Not Implemented |
UL0114 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,442 | $2,370 | Not Implemented |
AM0225 # 09 Y:1994 | 09 | 1994 | MODIFY MATERIAL APPLICATION METHODS | $0 | $7,500 | Implemented |
AM0225 # 02 Y:1994 | 02 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $13,670 | $15,000 | Implemented |
AM0225 # 05 Y:1994 | 05 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $730 | $200 | Implemented |
AM0225 # 03 Y:1994 | 03 | 1994 | OPTIMIZE PLANT POWER FACTOR | $10,500 | $13,000 | Not Implemented |
AM0225 # 08 Y:1994 | 08 | 1994 | IMPROVED MATERIAL HANDLING (MIXING AND TRANSFER) | $0 | $7,500 | Not Implemented |
AM0225 # 07 Y:1994 | 07 | 1994 | MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT | $290 | $0 | Implemented |
AM0225 # 04 Y:1994 | 04 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,260 | $0 | Implemented |
AM0225 # 06 Y:1994 | 06 | 1994 | USE A RAG RECYCLE SERVICE | $1,440 | $7,900 | Implemented |
AM0225 # 01 Y:1994 | 01 | 1994 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $33,100 | $81,000 | Implemented |
ND0201 # 03 Y:1994 | 03 | 1994 | INSTALL OCCUPANCY SENSORS | $2,915 | $600 | Not Implemented |