Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

360

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0120 # 05 Y:1995 05 1995 INSULATE BARE EQUIPMENT $5,311 $115 Implemented
IA0120 # 04 Y:1995 04 1995 USE SYNTHETIC LUBRICANT $959 $700 Implemented
IA0120 # 03 Y:1995 03 1995 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $5,316 $7,300 Not Implemented
IA0120 # 02 Y:1995 02 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,990 $135 Implemented
IA0120 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $10,907 $1,065 Not Implemented
MS0033 # 03 Y:1995 03 1995 INSTALL TIMERS AND/OR THERMOSTATS $393 $730 Not Implemented
MS0033 # 02 Y:1995 02 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,336 $2,170 Implemented
MS0033 # 01 Y:1995 01 1995 OPTIMIZE PLANT POWER FACTOR $16,206 $7,500 Implemented
MS0033 # 04 Y:1995 04 1995 RECOVER WASTE HEAT FROM EQUIPMENT $3,552 $5,640 Not Implemented
MS0033 # 05 Y:1995 05 1995 DIRECT WARMEST AIR TO COMBUSTION INTAKE $152,895 $101,700 Not Implemented
ND0217 # 08 Y:1995 08 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $21 $0 Implemented
ND0217 # 07 Y:1995 07 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $111 $390 Implemented
ND0217 # 06 Y:1995 06 1995 INSTALL OCCUPANCY SENSORS $168 $800 Implemented
ND0217 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,328 $7,375 Implemented
ND0217 # 02 Y:1995 02 1995 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $858 $0 Implemented
ND0217 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $445 $1,200 Implemented
ND0217 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $250 $200 Implemented
ND0217 # 04 Y:1995 04 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $440 $100 Implemented
OR0239 # 02 Y:1995 02 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $300 $807 Implemented
OR0239 # 03 Y:1995 03 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $484 $3,050 Not Implemented
MA0343 # 01 Y:1995 01 1995 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $26,616 $37,300 Not Implemented
MA0343 # 02 Y:1995 02 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $8,446 $9,000 Not Implemented
MA0343 # 03 Y:1995 03 1995 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,559 $3,300 Not Implemented
MA0343 # 04 Y:1995 04 1995 ELIMINATE COMBUSTIBLE GAS IN FLUE GAS $2,131 $1,750 Not Implemented
MA0343 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,114 $6,330 Implemented