Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
139
matching recommendationsSIC | 331 | Blast Furnace And Basic Steel Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0194 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,741 | $8,162 | Not Implemented |
IC0194 # 02 Y:2017 | 02 | 2017 | OPTIMIZE PLANT POWER FACTOR | $87,344 | $137,763 | Implemented |
IC0194 # 01 Y:2017 | 01 | 2017 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $124,626 | $220,275 | Implemented |
UD0817 # 06 Y:2010 | 06 | 2010 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,712 | $7,628 | Not Implemented |
UD0817 # 03 Y:2010 | 03 | 2010 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $9,387 | $0 | Not Implemented |
UD0817 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,364 | $1,876 | Not Implemented |
UD0817 # 02 Y:2010 | 02 | 2010 | OPTIMIZE PLANT POWER FACTOR | $63,586 | $41,250 | Not Implemented |
UD0817 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,546 | $3,000 | Not Implemented |
UD0817 # 01 Y:2010 | 01 | 2010 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $66,672 | $600 | Implemented |
UD0817 # 08 Y:2010 | 08 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,696 | $2,250 | Not Implemented |
UD0817 # 11 Y:2010 | 11 | 2010 | USE OPTIMUM TEMPERATURE | $8,137 | $0 | Implemented |
UD0817 # 14 Y:2010 | 14 | 2010 | RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION | $300 | $50 | Not Implemented |
UD0817 # 17 Y:2010 | 17 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $18,312 | $36,624 | Not Implemented |
UD0817 # 09 Y:2010 | 09 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,120 | $0 | Implemented |
UD0817 # 07 Y:2010 | 07 | 2010 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $628 | $0 | Implemented |
UD0817 # 12 Y:2010 | 12 | 2010 | COVER OPEN TANKS | $10,386 | $0 | Implemented |
UD0817 # 10 Y:2010 | 10 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,001 | $2,366 | Not Implemented |
UD0817 # 15 Y:2010 | 15 | 2010 | INSULATE BARE EQUIPMENT | $3,996 | $0 | Implemented |
UD0817 # 13 Y:2010 | 13 | 2010 | INSULATE BARE EQUIPMENT | $21,893 | $0 | Implemented |
UD0817 # 18 Y:2010 | 18 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,624 | $5,686 | Not Implemented |
UD0817 # 16 Y:2010 | 16 | 2010 | REDESIGN PROCESS | $357,330 | $0 | Not Implemented |
IC0084 # 08 Y:2004 | 08 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $48,922 | $200 | Implemented |
IC0084 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $2,024 | $430,000 | Not Implemented |
IC0084 # 09 Y:2004 | 09 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $124,469 | $513 | Implemented |
IC0084 # 01 Y:2004 | 01 | 2004 | INCREASE AMOUNT OF CONDENSATE RETURNED | $144,862 | $13,907 | Not Implemented |