IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,064

matching recommendations
Reset
SIC 331 Blast Furnace And Basic Steel Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0136 # 01 Y:1992 01 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,792 $2,981 Implemented
WI0136 # 02 Y:1992 02 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,714 $0 Implemented
WI0136 # 03 Y:1992 03 1992 INSTALL AUTOMATIC STACK DAMPER $3,416 $2,300 Implemented
WI0136 # 04 Y:1992 04 1992 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,478 $300 Implemented
WI0136 # 05 Y:1992 05 1992 INSTALL STORM WINDOWS AND DOORS $325 $195 Implemented
WI0136 # 06 Y:1992 06 1992 INSTALL TIMERS AND/OR THERMOSTATS $226 $200 Implemented
WI0136 # 07 Y:1992 07 1992 INSULATE BARE EQUIPMENT $1,350 $320 Not Implemented
WI0136 # 08 Y:1992 08 1992 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,333 $0 Not Implemented
WI0136 # 09 Y:1992 09 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $931 $1,500 Not Implemented
WI0136 # 10 Y:1992 10 1992 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $475 $450 Not Implemented
MA0225 # 01 Y:1991 01 1991 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $8,474 $43,800 Not Implemented
MA0225 # 02 Y:1991 02 1991 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $5,481 $11,200 Not Implemented
MA0225 # 03 Y:1991 03 1991 INSTALL / REPAIR INSULATION ON STEAM LINES $1,764 $2,625 Not Implemented
MA0225 # 04 Y:1991 04 1991 INSTALL SET-BACK TIMERS $1,367 $660 Implemented
MA0225 # 05 Y:1991 05 1991 REPAIR OR REPLACE STEAM TRAPS $970 $970 Implemented
MA0225 # 06 Y:1991 06 1991 INSULATE BARE EQUIPMENT $987 $689 Not Implemented
MA0225 # 07 Y:1991 07 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $551 $0 Implemented
MA0225 # 08 Y:1991 08 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $341 $550 Not Implemented
SD0007 # 01 Y:1991 01 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $223 $243 Implemented
SD0007 # 02 Y:1991 02 1991 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,105 $2,338 Implemented
SD0007 # 03 Y:1991 03 1991 COVER OPEN TANKS $1,377 $600 Implemented
SD0007 # 04 Y:1991 04 1991 INSTALL SET-BACK TIMERS $464 $600 Implemented
SD0007 # 05 Y:1991 05 1991 KEEP LAMPS AND REFLECTORS CLEAN $560 $660 Implemented
SD0007 # 06 Y:1991 06 1991 KEEP LAMPS AND REFLECTORS CLEAN $1,864 $6,280 Implemented
SD0007 # 07 Y:1991 07 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $213 $160 Implemented