Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
39
matching recommendationsSIC | 332 | Iron And Steel Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0162 # 07 Y:1992 | 07 | 1992 | REDESIGN PROCESS | $15,590 | $130,000 | Not Implemented |
OR0162 # 06 Y:1992 | 06 | 1992 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $26,207 | $150,000 | Implemented |
OR0162 # 05 Y:1992 | 05 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $4,388 | $14,272 | Not Implemented |
OR0162 # 04 Y:1992 | 04 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,666 | $5,359 | Implemented |
OR0162 # 03 Y:1992 | 03 | 1992 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $524 | $750 | Implemented |
OR0162 # 02 Y:1992 | 02 | 1992 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,784 | $2,920 | Implemented |
OR0120 # 02 Y:1991 | 02 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,938 | $3,000 | Not Implemented |
OR0120 # 05 Y:1991 | 05 | 1991 | INSULATE BARE EQUIPMENT | $50 | $1,095 | Not Implemented |
OR0120 # 04 Y:1991 | 04 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $113 | $226 | Not Implemented |
OR0120 # 03 Y:1991 | 03 | 1991 | OPTIMIZE PLANT POWER FACTOR | $1,000 | $1,425 | Not Implemented |
OR0120 # 01 Y:1991 | 01 | 1991 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $3,060 | $2,900 | Not Implemented |
OR0089 # 01 Y:1990 | 01 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,753 | $8,531 | Not Implemented |
OR0089 # 03 Y:1990 | 03 | 1990 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $96 | $181 | Not Implemented |
OR0089 # 02 Y:1990 | 02 | 1990 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $14,100 | $5,000 | Implemented |