Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47
matching recommendationsSIC | 332 | Iron And Steel Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0238 # 02 Y:1987 | 02 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $964 | $0 | Not Implemented |
OK0238 # 06 Y:1987 | 06 | 1987 | USE OPTIMUM THICKNESS INSULATION | $1,643 | $6,000 | Not Implemented |
OK0238 # 01 Y:1987 | 01 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $263 | $105 | Not Implemented |
OK0238 # 05 Y:1987 | 05 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,923 | $28,665 | Not Implemented |
OK0238 # 07 Y:1987 | 07 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,369 | $1,219 | Not Implemented |
OK0238 # 03 Y:1987 | 03 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $17,160 | $1,500 | Not Implemented |
OK0238 # 04 Y:1987 | 04 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,068 | $2,500 | Not Implemented |
OK0230 # 01 Y:1987 | 01 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $999 | $0 | Implemented |
OK0230 # 04 Y:1987 | 04 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $331 | $55 | Implemented |
OK0230 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $105 | $154 | Not Implemented |
OK0230 # 05 Y:1987 | 05 | 1987 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $23,577 | $4,125 | Implemented |
OK0230 # 02 Y:1987 | 02 | 1987 | INSULATE BARE EQUIPMENT | $669 | $1,450 | Not Implemented |
WI0002 # 01 Y:1987 | 01 | 1987 | IMPROVE LUBRICATION PRACTICES | $11,988 | $3,268 | Implemented |
WI0002 # 02 Y:1987 | 02 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,806 | $0 | Implemented |
WI0002 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,776 | $3,998 | Implemented |
WI0002 # 06 Y:1987 | 06 | 1987 | OPTIMIZE PLANT POWER FACTOR | $5,773 | $12,000 | Implemented |
UD0236 # 01 Y:1987 | 01 | 1987 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $102,264 | $500,000 | Not Implemented |
UD0236 # 02 Y:1987 | 02 | 1987 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $7,157 | $0 | Implemented |
UD0236 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,089 | $2,400 | Not Implemented |
UD0236 # 04 Y:1987 | 04 | 1987 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $6,699 | $28,000 | Not Implemented |
GT0320 # 01 Y:1987 | 01 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $450 | $300 | Implemented |
GT0320 # 02 Y:1987 | 02 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $16,900 | $50,000 | Implemented |
GT0320 # 03 Y:1987 | 03 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $11,700 | $28,500 | Not Implemented |
GT0320 # 04 Y:1987 | 04 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,400 | $5,170 | Implemented |
GT0320 # 05 Y:1987 | 05 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $350 | $520 | Implemented |