Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
35
matching recommendationsSIC | 3324 | Steel Investment Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0420 # 08 Y:2013 | 08 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,994 | $1,000 | Implemented |
UM0420 # 09 Y:2013 | 09 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,821 | $1,000 | Implemented |
UM0420 # 01 Y:2013 | 01 | 2013 | INSULATE BARE EQUIPMENT | $7,589 | $3,000 | Not Implemented |
UM0420 # 02 Y:2013 | 02 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $3,958 | $500 | Implemented |
UM0420 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,854 | $7,237 | Not Implemented |
UM0420 # 04 Y:2013 | 04 | 2013 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $3,081 | $10,000 | Not Implemented |
UM0420 # 06 Y:2013 | 06 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $672 | $2,300 | Not Implemented |
UM0420 # 07 Y:2013 | 07 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,530 | $10,000 | Not Implemented |
UM0420 # 05 Y:2013 | 05 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,312 | $200 | Implemented |
IC0163 # 02 Y:2009 | 02 | 2009 | INSTALL OCCUPANCY SENSORS | $635 | $538 | Implemented |
IC0163 # 10 Y:2009 | 10 | 2009 | $1,689,703 | $0 | Implemented | |
IC0163 # 09 Y:2009 | 09 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $260 | $0 | Not Implemented |
IC0163 # 08 Y:2009 | 08 | 2009 | RECYCLE WHITE WATER | $2,034 | $771 | Implemented |
IC0163 # 07 Y:2009 | 07 | 2009 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $6,925 | $17,000 | Implemented |
IC0163 # 06 Y:2009 | 06 | 2009 | USE RADIANT HEATER FOR SPOT HEATING | $9,226 | $39,560 | Not Implemented |
IC0163 # 05 Y:2009 | 05 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,247 | $0 | Not Implemented |
IC0163 # 04 Y:2009 | 04 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $357 | $0 | Not Implemented |
IC0163 # 03 Y:2009 | 03 | 2009 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $3,314 | $102 | Implemented |
IC0163 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $528 | $332 | Implemented |
UM0326 # 03 Y:2007 | 03 | 2007 | COVER OPEN TANKS | $4,631 | $220 | Implemented |
UM0326 # 04 Y:2007 | 04 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,591 | $500 | Implemented |
UM0326 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,234 | $675 | Implemented |
UM0326 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,191 | $1,860 | Implemented |
UM0326 # 07 Y:2007 | 07 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,476 | $2,200 | Implemented |
UM0326 # 08 Y:2007 | 08 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,092 | $204 | Implemented |