Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
256
matching recommendationsSIC | 333 | Primary Nonferrous Metals |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0044 # 05 Y:2009 | 05 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,268 | $0 | Not Implemented |
MZ0044 # 06 Y:2009 | 06 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $15,312 | $10,000 | Not Implemented |
MZ0044 # 07 Y:2009 | 07 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,155 | $10,000 | Not Implemented |
OK0780 # 01 Y:2009 | 01 | 2009 | ADJUST BURNERS FOR EFFICIENT OPERATION | $134,300 | $0 | Implemented |
OK0780 # 02 Y:2009 | 02 | 2009 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $66,265 | $0 | Implemented |
OK0780 # 03 Y:2009 | 03 | 2009 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $155,286 | $17,711 | Not Implemented |
OK0780 # 04 Y:2009 | 04 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $853,347 | $1,183,200 | Not Implemented |
OK0780 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,642 | $21,120 | Not Implemented |
OK0780 # 06 Y:2009 | 06 | 2009 | INSTALL OCCUPANCY SENSORS | $24,432 | $100,710 | Not Implemented |
OK0780 # 07 Y:2009 | 07 | 2009 | INSTALL OCCUPANCY SENSORS | $31,638 | $89,399 | Not Implemented |
OK0780 # 08 Y:2009 | 08 | 2009 | INSTALL OCCUPANCY SENSORS | $312 | $732 | Not Implemented |
OK0780 # 09 Y:2009 | 09 | 2009 | INSTALL OCCUPANCY SENSORS | $1,517 | $274 | Not Implemented |
OK0780 # 10 Y:2009 | 10 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,725 | $10,000 | Implemented |
OK0780 # 11 Y:2009 | 11 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,925 | $412 | Implemented |
OK0780 # 12 Y:2009 | 12 | 2009 | INSTALL WIND POWERED ELECTRIC GENERATOR | $1,048,470 | $5,670,000 | Not Implemented |
OK0780 # 13 Y:2009 | 13 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,206 | $2,398 | Implemented |
OK0780 # 14 Y:2009 | 14 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,341 | $0 | Implemented |
UA0016 # 01 Y:2008 | 01 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $60,322 | $10,000 | Implemented |
UA0016 # 02 Y:2008 | 02 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $22,023 | $20,000 | Not Implemented |
UA0016 # 03 Y:2008 | 03 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $17,135 | $2,000 | Not Implemented |
UA0016 # 04 Y:2008 | 04 | 2008 | INCREASE AMOUNT OF CONDENSATE RETURNED | $171,000 | $95,000 | Not Implemented |
UA0016 # 05 Y:2008 | 05 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,808 | $460 | Not Implemented |
UA0016 # 06 Y:2008 | 06 | 2008 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $30,000 | $50,000 | Not Implemented |
UA0016 # 07 Y:2008 | 07 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $52,000 | $150,000 | Not Implemented |
SF0349 # 01 Y:2007 | 01 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $6,853 | $0 | Implemented |