Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsSIC | 333 | Primary Nonferrous Metals |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0417 # 08 Y:2012 | 08 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,721 | $500 | Not Implemented |
UM0417 # 07 Y:2012 | 07 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,464 | $35,000 | Not Implemented |
UM0417 # 06 Y:2012 | 06 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $305 | $100 | Not Implemented |
UM0417 # 05 Y:2012 | 05 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $6,000 | $200 | Implemented |
UM0417 # 04 Y:2012 | 04 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,038 | $200 | Not Implemented |
UM0417 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,780 | $58,125 | Implemented |
UM0417 # 02 Y:2012 | 02 | 2012 | INSTALL OCCUPANCY SENSORS | $2,390 | $3,500 | Not Implemented |
UM0417 # 03 Y:2012 | 03 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,907 | $5,000 | Not Implemented |
OR0592 # 06 Y:2012 | 06 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $919 | $1,805 | Not Implemented |
OR0592 # 05 Y:2012 | 05 | 2012 | ELIMINATE/REDUCE AN OPERATION | $2,222 | $120 | Not Implemented |
OR0592 # 04 Y:2012 | 04 | 2012 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $15,020 | $0 | Implemented |
OR0592 # 03 Y:2012 | 03 | 2012 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $40,400 | $70,000 | Implemented |
OR0592 # 02 Y:2012 | 02 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $27,815 | $42,303 | Not Implemented |
OR0592 # 01 Y:2012 | 01 | 2012 | REDUCE SCRAP PRODUCTION | $413,713 | $260,000 | Not Implemented |
UD0862 # 11 Y:2012 | 11 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,020 | $2,000 | Not Implemented |
UD0862 # 10 Y:2012 | 10 | 2012 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $2,963 | $10,000 | Not Implemented |
UD0862 # 09 Y:2012 | 09 | 2012 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $3,985 | $10,000 | Not Implemented |
UD0862 # 08 Y:2012 | 08 | 2012 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,095 | $3,000 | Not Implemented |
UD0862 # 07 Y:2012 | 07 | 2012 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $14,974 | $30,000 | Not Implemented |
UD0862 # 06 Y:2012 | 06 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,687 | $11,000 | Not Implemented |
UD0862 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,711 | $410 | Not Implemented |
UD0862 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,018 | $1,000 | Not Implemented |
UD0862 # 03 Y:2012 | 03 | 2012 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,270 | $11,275 | Not Implemented |
UD0862 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,513 | $67,068 | Not Implemented |
UD0862 # 01 Y:2012 | 01 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,703 | $0 | Not Implemented |