Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsSIC | 3331 | Primary Copper |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0862 # 11 Y:2012 | 11 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,020 | $2,000 | Not Implemented |
UD0862 # 10 Y:2012 | 10 | 2012 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $2,963 | $10,000 | Not Implemented |
UD0862 # 09 Y:2012 | 09 | 2012 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $3,985 | $10,000 | Not Implemented |
UD0862 # 08 Y:2012 | 08 | 2012 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,095 | $3,000 | Not Implemented |
UD0862 # 07 Y:2012 | 07 | 2012 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $14,974 | $30,000 | Not Implemented |
UD0862 # 06 Y:2012 | 06 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,687 | $11,000 | Not Implemented |
UD0862 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,711 | $410 | Not Implemented |
UD0862 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,018 | $1,000 | Not Implemented |
UD0862 # 03 Y:2012 | 03 | 2012 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,270 | $11,275 | Not Implemented |
UD0862 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,513 | $67,068 | Not Implemented |
UD0862 # 01 Y:2012 | 01 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,703 | $0 | Not Implemented |
OK0780 # 13 Y:2009 | 13 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,206 | $2,398 | Implemented |
OK0780 # 14 Y:2009 | 14 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,341 | $0 | Implemented |
OK0780 # 01 Y:2009 | 01 | 2009 | ADJUST BURNERS FOR EFFICIENT OPERATION | $134,300 | $0 | Implemented |
OK0780 # 12 Y:2009 | 12 | 2009 | INSTALL WIND POWERED ELECTRIC GENERATOR | $1,048,470 | $5,670,000 | Not Implemented |
OK0780 # 11 Y:2009 | 11 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,925 | $412 | Implemented |
OK0780 # 10 Y:2009 | 10 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,725 | $10,000 | Implemented |
OK0780 # 09 Y:2009 | 09 | 2009 | INSTALL OCCUPANCY SENSORS | $1,517 | $274 | Not Implemented |
OK0780 # 08 Y:2009 | 08 | 2009 | INSTALL OCCUPANCY SENSORS | $312 | $732 | Not Implemented |
OK0780 # 07 Y:2009 | 07 | 2009 | INSTALL OCCUPANCY SENSORS | $31,638 | $89,399 | Not Implemented |
OK0780 # 06 Y:2009 | 06 | 2009 | INSTALL OCCUPANCY SENSORS | $24,432 | $100,710 | Not Implemented |
OK0780 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,642 | $21,120 | Not Implemented |
OK0780 # 04 Y:2009 | 04 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $853,347 | $1,183,200 | Not Implemented |
OK0780 # 03 Y:2009 | 03 | 2009 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $155,286 | $17,711 | Not Implemented |
OK0780 # 02 Y:2009 | 02 | 2009 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $66,265 | $0 | Implemented |