Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

16

matching recommendations
Reset
SIC 3341 Secondary Nonferrous Metals
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0176 # 01 Y:2004 01 2004 PREHEAT COMBUSTION AIR WITH WASTE HEAT $114,214 $25,000 Implemented
LE0176 # 02 Y:2004 02 2004 PREHEAT COMBUSTION AIR WITH WASTE HEAT $20,766 $1,500 Not Implemented
LE0176 # 03 Y:2004 03 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $19,851 $1,000 Not Implemented
LE0176 # 04 Y:2004 04 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $14,480 $5,000 Not Implemented
LE0176 # 05 Y:2004 05 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $11,003 $1,000 Implemented
LE0176 # 06 Y:2004 06 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $8,825 $0 Implemented
LE0176 # 07 Y:2004 07 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $985 $0 Not Implemented
HO0216 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,337 $24,765 Not Implemented
HO0216 # 02 Y:2000 02 2000 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,354 $3,000 Not Implemented
HO0216 # 03 Y:2000 03 2000 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $4,650 $548 Implemented
HO0216 # 04 Y:2000 04 2000 INSTALL OCCUPANCY SENSORS $11,898 $5,000 Implemented
HO0216 # 05 Y:2000 05 2000 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $9,645 $10,005 Implemented
HO0216 # 06 Y:2000 06 2000 TURN OFF EQUIPMENT WHEN NOT IN USE $4,569 $0 Not Implemented
HO0216 # 07 Y:2000 07 2000 INSULATE BARE EQUIPMENT $49,535 $11,088 Not Implemented
HO0216 # 08 Y:2000 08 2000 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $10,726 $4,167 Not Implemented
HO0216 # 09 Y:2000 09 2000 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $1,665 $222 Implemented