Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,036
matching recommendationsSIC | 335 | Nonferrous Rolling And Drawing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0218 # 09 Y:2005 | 09 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,729 | $1,878 | Implemented |
SU0218 # 10 Y:2005 | 10 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,025 | $15,000 | Not Implemented |
SU0218 # 11 Y:2005 | 11 | 2005 | REDUCE VENTILATION AIR | $14,692 | $17,995 | Not Implemented |
SU0218 # 12 Y:2005 | 12 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,220 | $53,200 | Implemented |
SU0218 # 13 Y:2005 | 13 | 2005 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $456 | $1,166 | Not Implemented |
SU0218 # 14 Y:2005 | 14 | 2005 | OPTIMIZE PLANT POWER FACTOR | $18,968 | $61,178 | Implemented |
WV0318 # 01 Y:2005 | 01 | 2005 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $39,332 | $8,388 | Implemented |
WV0318 # 02 Y:2005 | 02 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $21,012 | $3,064 | Implemented |
WV0318 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,845 | $6,470 | Implemented |
WV0318 # 04 Y:2005 | 04 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,757 | $620 | Implemented |
WV0318 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,670 | $587 | Implemented |
WV0318 # 06 Y:2005 | 06 | 2005 | COVER OPEN TANKS | $5,974 | $12,120 | Not Implemented |
WV0318 # 07 Y:2005 | 07 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $4,198 | $330 | Implemented |
WV0318 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,582 | $11,537 | Not Implemented |
WV0318 # 09 Y:2005 | 09 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,258 | $360 | Implemented |
WV0318 # 10 Y:2005 | 10 | 2005 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,532 | $5,220 | Implemented |
UD0721 # 01 Y:2005 | 01 | 2005 | RECOVER MECHANICAL ENERGY | $206,969 | $413,938 | Implemented |
UD0721 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,010 | $86,100 | Implemented |
UD0721 # 03 Y:2005 | 03 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $11,745 | $160 | Implemented |
UD0721 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $11,579 | $12,000 | Implemented |
UD0721 # 05 Y:2005 | 05 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,580 | $0 | Implemented |
UD0721 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,040 | $11,100 | Implemented |
UD0721 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $2,714 | $345 | Not Implemented |
UD0721 # 08 Y:2005 | 08 | 2005 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,229 | $860 | Not Implemented |
UD0721 # 09 Y:2005 | 09 | 2005 | INSULATE BARE EQUIPMENT | $675 | $1,820 | Not Implemented |