Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
19
matching recommendationsSIC | 335 | Nonferrous Rolling And Drawing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0080 # 03 Y:1986 | 03 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $93,569 | $0 | Not Implemented |
MA0080 # 02 Y:1986 | 02 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $44,537 | $600 | Implemented |
MA0080 # 01 Y:1986 | 01 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,100 | $3,000 | Implemented |
LT0077 # 06 Y:1986 | 06 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,400 | $0 | Implemented |
LT0077 # 05 Y:1986 | 05 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,457 | $1,160 | Implemented |
LT0077 # 04 Y:1986 | 04 | 1986 | COVER OPEN TANKS | $1,540 | $20 | Implemented |
LT0077 # 03 Y:1986 | 03 | 1986 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $5,530 | $11,640 | Not Implemented |
LT0077 # 02 Y:1986 | 02 | 1986 | INSTALL SET-BACK TIMERS | $470 | $130 | Not Implemented |
LT0077 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $373 | $170 | Implemented |
LT0066 # 04 Y:1986 | 04 | 1986 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $84 | $8 | Not Implemented |
LT0066 # 03 Y:1986 | 03 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $837 | $334 | Not Implemented |
LT0066 # 02 Y:1986 | 02 | 1986 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $9,230 | $12,000 | Implemented |
LT0066 # 01 Y:1986 | 01 | 1986 | INSTALL SET-BACK TIMERS | $602 | $210 | Not Implemented |
AT0039 # 01 Y:1986 | 01 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $834 | $859 | Implemented |
AT0039 # 06 Y:1986 | 06 | 1986 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $46,699 | $227 | Implemented |
AT0039 # 05 Y:1986 | 05 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $11,108 | $14,000 | Implemented |
AT0039 # 04 Y:1986 | 04 | 1986 | INSULATE BARE EQUIPMENT | $9,830 | $1,640 | Implemented |
AT0039 # 03 Y:1986 | 03 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $948 | $2,250 | Implemented |
AT0039 # 02 Y:1986 | 02 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,360 | $1,700 | Not Implemented |