Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
76
matching recommendationsSIC | 3354 | Aluminum Extruded Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0139 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,014 | $50,232 | Not Implemented |
MI0139 # 02 Y:2006 | 02 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $26,909 | $30 | Implemented |
MI0139 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $36,785 | $1,074 | Implemented |
UF0323 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,288 | $23,205 | Implemented |
UF0323 # 08 Y:2003 | 08 | 2003 | INSTALL OCCUPANCY SENSORS | $1,385 | $831 | Not Implemented |
UF0323 # 02 Y:2003 | 02 | 2003 | ADD AREA LIGHTING SWITCHES | $2,366 | $4,075 | Not Implemented |
UF0323 # 03 Y:2003 | 03 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $12,002 | $0 | Not Implemented |
UF0323 # 04 Y:2003 | 04 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $26,966 | $104,168 | Implemented |
UF0323 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,475 | $370 | Implemented |
UF0323 # 06 Y:2003 | 06 | 2003 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $76,790 | $65 | Implemented |
UF0323 # 07 Y:2003 | 07 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,852 | $618 | Not Implemented |
UF0323 # 09 Y:2003 | 09 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $774 | $3,496 | Not Implemented |
UF0323 # 10 Y:2003 | 10 | 2003 | DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS | $69,343 | $420,000 | Implemented |
UF0302 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $8,740 | $1,212 | Not Implemented |
UF0302 # 05 Y:2002 | 05 | 2002 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,883 | $2,330 | Implemented |
UF0302 # 06 Y:2002 | 06 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $36,009 | $132,451 | Not Implemented |
UF0302 # 07 Y:2002 | 07 | 2002 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $4,587 | $0 | Implemented |
UF0302 # 08 Y:2002 | 08 | 2002 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,091 | $0 | Not Implemented |
UF0302 # 09 Y:2002 | 09 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $20,631 | $15,352 | Not Implemented |
UF0302 # 10 Y:2002 | 10 | 2002 | INSTALL AUTOMATIC PACKING EQUIPMENT | $111,281 | $400,000 | Not Implemented |
UF0302 # 03 Y:2002 | 03 | 2002 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $21,535 | $100,405 | Not Implemented |
UF0302 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,992 | $550 | Implemented |
UF0302 # 01 Y:2002 | 01 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,265 | $3,773 | Implemented |
MI0033 # 01 Y:2002 | 01 | 2002 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $213,180 | $138,361 | Not Implemented |
MI0033 # 02 Y:2002 | 02 | 2002 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $7,472 | $8,890 | Not Implemented |