Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

106

matching recommendations
Reset
SIC 336 Nonferrous Foundries (castings)
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0124 # 06 Y:1995 06 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $245 $200 n/a
IA0124 # 07 Y:1995 07 1995 MINIMIZE WATER USAGE $6,925 $9,600 n/a
IA0124 # 08 Y:1995 08 1995 MINIMIZE WATER USAGE $2,308 $100 n/a
IA0120 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $10,907 $1,065 Not Implemented
IA0120 # 02 Y:1995 02 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,990 $135 Implemented
IA0120 # 03 Y:1995 03 1995 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $5,316 $7,300 Not Implemented
IA0120 # 04 Y:1995 04 1995 USE SYNTHETIC LUBRICANT $959 $700 Implemented
IA0120 # 05 Y:1995 05 1995 INSULATE BARE EQUIPMENT $5,311 $115 Implemented
IA0120 # 06 Y:1995 06 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,503 $11,164 Not Implemented
IA0120 # 07 Y:1995 07 1995 INSTALL OCCUPANCY SENSORS $1,508 $916 Not Implemented
IA0120 # 08 Y:1995 08 1995 RECOVER WASTE HEAT FROM EQUIPMENT $281 $740 Not Implemented
IA0112 # 01 Y:1995 01 1995 SHUT OFF PILOTS IN STANDBY EQUIPMENT $38,404 $325 Implemented
IA0112 # 02 Y:1995 02 1995 COVER OPEN TANKS $12,802 $5,018 Not Implemented
IA0112 # 03 Y:1995 03 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $8,978 $50 Implemented
IA0112 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,062 $9,608 Implemented
IA0112 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,490 $951 Implemented
IA0112 # 06 Y:1995 06 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,463 $500 Implemented
IA0112 # 07 Y:1995 07 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,119 $325 Implemented
IA0112 # 08 Y:1995 08 1995 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,454 $3,000 Not Implemented
IA0045 # 01 Y:1993 01 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $15,690 $660 Implemented
IA0045 # 02 Y:1993 02 1993 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $3,118 $1,188 Not Implemented
IA0045 # 03 Y:1993 03 1993 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $4,196 $2,893 Implemented
IA0045 # 04 Y:1993 04 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,763 $714 Not Implemented
IA0045 # 05 Y:1993 05 1993 INSTALL OCCUPANCY SENSORS $2,302 $1,215 Not Implemented
KU0257 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,773 $2,670 Not Implemented