Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,412
matching recommendationsSIC | 336 | Nonferrous Foundries (castings) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0124 # 05 Y:1995 | 05 | 1995 | INSTALL OCCUPANCY SENSORS | $219 | $535 | n/a |
IA0124 # 06 Y:1995 | 06 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $245 | $200 | n/a |
IA0124 # 07 Y:1995 | 07 | 1995 | MINIMIZE WATER USAGE | $6,925 | $9,600 | n/a |
IA0124 # 08 Y:1995 | 08 | 1995 | MINIMIZE WATER USAGE | $2,308 | $100 | n/a |
WV0073 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,063 | $1,113 | Implemented |
WV0073 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,102 | $11,650 | Implemented |
WV0073 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,344 | $2,220 | Not Implemented |
WV0073 # 04 Y:1995 | 04 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,159 | $1,800 | Not Implemented |
WV0073 # 05 Y:1995 | 05 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $952 | $200 | Implemented |
WV0073 # 06 Y:1995 | 06 | 1995 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $5,798 | $3,300 | Not Implemented |
WV0073 # 07 Y:1995 | 07 | 1995 | INSULATE BARE EQUIPMENT | $11,972 | $1,278 | Implemented |
WV0073 # 08 Y:1995 | 08 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $15,977 | $5,000 | Implemented |
IA0120 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,907 | $1,065 | Not Implemented |
IA0120 # 02 Y:1995 | 02 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,990 | $135 | Implemented |
IA0120 # 03 Y:1995 | 03 | 1995 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,316 | $7,300 | Not Implemented |
IA0120 # 04 Y:1995 | 04 | 1995 | USE SYNTHETIC LUBRICANT | $959 | $700 | Implemented |
IA0120 # 05 Y:1995 | 05 | 1995 | INSULATE BARE EQUIPMENT | $5,311 | $115 | Implemented |
IA0120 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,503 | $11,164 | Not Implemented |
IA0120 # 07 Y:1995 | 07 | 1995 | INSTALL OCCUPANCY SENSORS | $1,508 | $916 | Not Implemented |
IA0120 # 08 Y:1995 | 08 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $281 | $740 | Not Implemented |
MS0033 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $16,206 | $7,500 | Implemented |
MS0033 # 02 Y:1995 | 02 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,336 | $2,170 | Implemented |
MS0033 # 03 Y:1995 | 03 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $393 | $730 | Not Implemented |
MS0033 # 04 Y:1995 | 04 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,552 | $5,640 | Not Implemented |
MS0033 # 05 Y:1995 | 05 | 1995 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $152,895 | $101,700 | Not Implemented |