Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,106
matching recommendationsSIC | 3363 | Aluminum Die-castings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0023 # 03 Y:1985 | 03 | 1985 | REVISE SMOKE CLEANUP FROM OPERATIONS | $6,061 | $1,447 | Implemented |
MA0023 # 04 Y:1985 | 04 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $450 | $66 | Implemented |
LT0001 # 01 Y:1984 | 01 | 1984 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $6,220 | $12,200 | Implemented |
LT0001 # 02 Y:1984 | 02 | 1984 | ADJUST VENTS TO MINIMIZE ENERGY USE | $10,250 | $900 | Not Implemented |
LT0001 # 03 Y:1984 | 03 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $14,340 | $0 | Implemented |
LT0001 # 04 Y:1984 | 04 | 1984 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,420 | $0 | Not Implemented |
LT0001 # 05 Y:1984 | 05 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $66,754 | $0 | Implemented |
TN0207 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $25,155 | $12,500 | Implemented |
TN0207 # 02 Y:1984 | 02 | 1984 | INSULATE BARE EQUIPMENT | $18,357 | $750 | Implemented |
TN0207 # 03 Y:1984 | 03 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,215 | $21,000 | Implemented |
TN0207 # 04 Y:1984 | 04 | 1984 | INSTALL SET-BACK TIMERS | $645 | $0 | Implemented |
TN0207 # 05 Y:1984 | 05 | 1984 | INSULATE BARE EQUIPMENT | $250 | $78 | Not Implemented |
UD0069 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,154 | $272 | Not Implemented |
UD0069 # 02 Y:1982 | 02 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $257 | $500 | Not Implemented |
UD0069 # 03 Y:1982 | 03 | 1982 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,195 | $3,000 | Not Implemented |
UD0069 # 04 Y:1982 | 04 | 1982 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $2,157 | $2,629 | Not Implemented |
UD0070 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $594 | $158 | Not Implemented |
UD0070 # 02 Y:1982 | 02 | 1982 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $6,051 | $10,000 | Implemented |
UD0070 # 03 Y:1982 | 03 | 1982 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $13,079 | $15,000 | Implemented |
UD0070 # 04 Y:1982 | 04 | 1982 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $34,531 | $43,000 | Not Implemented |
GT0126 # 01 Y:1982 | 01 | 1982 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $9,264 | $5,890 | Not Implemented |
GT0126 # 02 Y:1982 | 02 | 1982 | COVER OPEN TANKS | $6,304 | $460 | Not Implemented |
GT0126 # 03 Y:1982 | 03 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,537 | $140 | Implemented |
GT0126 # 04 Y:1982 | 04 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $417 | $400 | Not Implemented |
GT0131 # 01 Y:1982 | 01 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $237 | $400 | Not Implemented |