IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,047

matching recommendations
Reset
SIC 339 Miscellaneous Primary Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0018 # 02 Y:1985 02 1985 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,840 $756 Implemented
MA0018 # 03 Y:1985 03 1985 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $12,935 $31,465 Implemented
OK0136 # 01 Y:1984 01 1984 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $124 $0 Implemented
OK0136 # 02 Y:1984 02 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $33 $92 Implemented
OK0136 # 03 Y:1984 03 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $80 $43 Implemented
OK0136 # 04 Y:1984 04 1984 INSTALL TIMERS AND/OR THERMOSTATS $163 $165 Not Implemented
OK0136 # 05 Y:1984 05 1984 INSULATE BARE EQUIPMENT $407 $300 Implemented
OK0136 # 06 Y:1984 06 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,353 $11,300 Not Implemented
OK0128 # 01 Y:1984 01 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $34,347 $800 Implemented
OK0128 # 02 Y:1984 02 1984 INSTALL TURBULATORS $10,851 $20,000 Not Implemented
OK0128 # 03 Y:1984 03 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $468 $972 Implemented
OK0128 # 04 Y:1984 04 1984 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,237 $650 Implemented
UD0071 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,990 $627 Not Implemented
UD0071 # 02 Y:1983 02 1983 INSTALL STORM WINDOWS AND DOORS $1,451 $2,000 Not Implemented
UD0071 # 03 Y:1983 03 1983 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $2,364 $3,680 Implemented
UD0071 # 04 Y:1983 04 1983 RECOVER WASTE HEAT FROM EQUIPMENT $6,519 $40,000 Not Implemented
UD0062 # 01 Y:1982 01 1982 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $10,658 $1,240 Not Implemented
UD0062 # 02 Y:1982 02 1982 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,859 $25,000 Not Implemented
TN0102 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $612 $1,000 Not Implemented
TN0102 # 02 Y:1982 02 1982 INSTALL / REPAIR INSULATION ON STEAM LINES $5,782 $4,500 Not Implemented
TN0102 # 03 Y:1982 03 1982 INSULATE BARE EQUIPMENT $3,389 $4,000 Not Implemented
TN0102 # 04 Y:1982 04 1982 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $3,134 $12,000 Not Implemented