Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

428

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0039 # 11 Y:1994 11 1994 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $1,900 $500 Not Implemented
NC0039 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,241 $2,018 Implemented
NC0022 # 01 Y:1994 01 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,088 $90 Implemented
NC0022 # 02 Y:1994 02 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $309 $10 Implemented
NC0022 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,432 $1,592 Implemented
NC0022 # 04 Y:1994 04 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,119 $9,280 Not Implemented
NC0022 # 05 Y:1994 05 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $145 $500 Not Implemented
NC0012 # 01 Y:1993 01 1993 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $14,358 $14,233 Not Implemented
NC0012 # 02 Y:1993 02 1993 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $27,321 $0 Not Implemented
NC0012 # 03 Y:1993 03 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,032 $4,500 Implemented
NC0012 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $12,829 $510 Implemented
NC0012 # 05 Y:1993 05 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $10,454 $500 Implemented
NC0004 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,514 $1,222 Implemented
NC0004 # 02 Y:1993 02 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,054 $690 Implemented
NC0004 # 03 Y:1993 03 1993 RECOVER AND REUSE COOLING WATER $834 $500 Not Implemented
NC0004 # 04 Y:1993 04 1993 RECOVER WASTE HEAT FROM EQUIPMENT $26,384 $1,500 Not Implemented
NC0004 # 05 Y:1993 05 1993 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $1,143 $1,100 Not Implemented
NC0004 # 06 Y:1993 06 1993 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $1,494 $4,500 Not Implemented
TN0435 # 01 Y:1991 01 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,971 $6,000 Implemented
TN0435 # 02 Y:1991 02 1991 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $2,926 $0 Implemented
TN0435 # 03 Y:1991 03 1991 KEEP LAMPS AND REFLECTORS CLEAN $2,939 $4,256 Implemented
TN0435 # 04 Y:1991 04 1991 INSTALL SET-BACK TIMERS $1,932 $0 Implemented
TN0435 # 05 Y:1991 05 1991 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $892 $190 Implemented
TN0435 # 06 Y:1991 06 1991 COVER OPEN TANKS $910 $315 Implemented
TN0435 # 07 Y:1991 07 1991 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $244 $410 Implemented