Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center North Carolina State
Assessment Year 1994
Principal Product Fire Protection Valves and Meters
NAICS n/a
SIC 3494 - Valves And Pipe Fittings, Nec
Sales $10,000,000-$50,000,000
# of Employees 163
Plant Area (Sq.Ft.) 141,000
Annual Production 0 Units
Production Hrs. Annual 6,000
Location (State) NC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $208,248 4,126,026 kWh $0.05
Natural Gas $43,254 7,972 MMBtu $5.43
TOTAL ENERGY COSTS $251,502
RECOMMENDED SAVINGS* $51,392 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $13,169
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,241
Cost:
$2,018
$4,241 84,994 - - $4,241
84,994
kWh
-
-
MMBtu
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$3,052
Cost:
$3,850
- - $3,052 - -
-
kWh
$3,052
-
MMBtu
03: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$1,432
Cost:
$1,500
$1,432 26,084 - - $1,432
26,084
kWh
-
-
MMBtu
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,710
Cost:
$600
$3,710 74,150 - - $3,710
74,150
kWh
-
-
MMBtu
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,600
Cost:
$420
$1,600 38,101 - - $1,600
38,101
kWh
-
-
MMBtu
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$5,307
Cost:
$2,500
- - $5,307 977 -
-
kWh
$5,307
977
MMBtu
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,306
Cost:
$5,070
$2,306 42,790 - - $2,306
42,790
kWh
-
-
MMBtu
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$156
Cost:
$570
$156 2,931 - - $156
2,931
kWh
-
-
MMBtu
09: 2.3137 USE POWER DURING OFF-PEAK PERIODS Savings:
$8,928
Cost:
-
$8,928 - - - $8,928
-
kWh
-
-
MMBtu
10: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$18,760
Cost:
$16,000
- - $18,760 3,507 -
-
kWh
$18,760
3,507
MMBtu
11: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$1,900
Cost:
$500
- - $1,900 350 -
-
kWh
$1,900
350
MMBtu
TOTAL RECOMMENDED Savings:
$51,392
Cost:
$33,028
$22,373 269,050 $29,019 4,834 $22,373
269,050
kWh
$29,019
4,834
MMBtu
TOTAL IMPLEMENTED Savings:
$13,169
Cost:
$2,018
$13,169 84,994 - - $13,169
84,994
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas