Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
850
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0413 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $77,291 | $154,121 | Implemented |
WV0413 # 04 Y:2010 | 04 | 2010 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $59,435 | $55,000 | Implemented |
WV0413 # 05 Y:2010 | 05 | 2010 | COVER OPEN TANKS | $41,697 | $9,404 | Not Implemented |
WV0413 # 06 Y:2010 | 06 | 2010 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $24,889 | $9,534 | Implemented |
WV0413 # 07 Y:2010 | 07 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $14,418 | $0 | Implemented |
WV0413 # 08 Y:2010 | 08 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,163 | $1,048 | Not Implemented |
WV0413 # 09 Y:2010 | 09 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $10,138 | $1,674 | Implemented |
WV0413 # 10 Y:2010 | 10 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $6,565 | $7,770 | Not Implemented |
WV0413 # 11 Y:2010 | 11 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,414 | $0 | Implemented |
WV0413 # 12 Y:2010 | 12 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,242 | $16,759 | Implemented |
WV0413 # 13 Y:2010 | 13 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,528 | $1,876 | Not Implemented |
WV0413 # 14 Y:2010 | 14 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,830 | $6,571 | Implemented |
WV0413 # 15 Y:2010 | 15 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,069 | $1,000 | Implemented |
WV0413 # 16 Y:2010 | 16 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $288 | $357 | Implemented |
WV0406 # 01 Y:2010 | 01 | 2010 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $165,791 | $87,000 | Not Implemented |
WV0406 # 02 Y:2010 | 02 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $75,243 | $91,000 | Not Implemented |
WV0406 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,098 | $49,200 | Implemented |
WV0406 # 04 Y:2010 | 04 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $15,356 | $7,809 | Not Implemented |
WV0406 # 05 Y:2010 | 05 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,767 | $65 | Not Implemented |
WV0406 # 06 Y:2010 | 06 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,089 | $245 | Not Implemented |
DL0047 # 01 Y:2010 | 01 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,774 | $0 | Implemented |
DL0047 # 02 Y:2010 | 02 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,044 | $0 | Not Implemented |
DL0047 # 03 Y:2010 | 03 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,212 | $0 | Implemented |
DL0047 # 04 Y:2010 | 04 | 2010 | DISCONNECT BALLASTS | $1,481 | $0 | Not Implemented |
DL0047 # 05 Y:2010 | 05 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,068 | $0 | Implemented |