Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,750

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0130 # 01 Y:1991 01 1991 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $33,213 $20,000 Not Implemented
WI0130 # 02 Y:1991 02 1991 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $5,028 $0 Not Implemented
WI0130 # 03 Y:1991 03 1991 IMPROVE LUBRICATION PRACTICES $4,776 $0 Not Implemented
WI0130 # 04 Y:1991 04 1991 RECOVER WASTE HEAT FROM EQUIPMENT $1,068 $3,100 Not Implemented
WI0130 # 05 Y:1991 05 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,149 $1,920 Not Implemented
WI0130 # 06 Y:1991 06 1991 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $565 $700 Not Implemented
WI0130 # 07 Y:1991 07 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $340 $0 Not Implemented
WI0130 # 08 Y:1991 08 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21 $17 Not Implemented
WI0132 # 01 Y:1991 01 1991 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,133 $2,100 Not Implemented
WI0132 # 02 Y:1991 02 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $541 $1,280 Not Implemented
WI0132 # 03 Y:1991 03 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $188 $33 Not Implemented
WI0132 # 04 Y:1991 04 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $433 $0 Not Implemented
WI0123 # 01 Y:1991 01 1991 INSTALL STORM WINDOWS AND DOORS $11,035 $46,642 Not Implemented
WI0123 # 02 Y:1991 02 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,766 $951 Not Implemented
WI0123 # 03 Y:1991 03 1991 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,946 $5,600 Not Implemented
WI0123 # 04 Y:1991 04 1991 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,556 $5,000 Not Implemented
WI0123 # 05 Y:1991 05 1991 INSTALL SET-BACK TIMERS $1,860 $0 Not Implemented
WI0123 # 06 Y:1991 06 1991 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $912 $0 Not Implemented
WI0123 # 07 Y:1991 07 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,455 $640 Not Implemented
WI0123 # 08 Y:1991 08 1991 INSTALL / REPAIR INSULATION ON STEAM LINES $1,292 $429 Not Implemented
WI0123 # 09 Y:1991 09 1991 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $825 $700 Not Implemented
WI0123 # 10 Y:1991 10 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $768 $500 Not Implemented
WI0118 # 01 Y:1991 01 1991 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $22,344 $0 Implemented
WI0118 # 02 Y:1991 02 1991 INSTALL TIMERS AND/OR THERMOSTATS $11,458 $200 Implemented
WI0118 # 03 Y:1991 03 1991 INSTALL TIMERS AND/OR THERMOSTATS $3,546 $200 Implemented