Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
494
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0395 # 02 Y:1993 | 02 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,656 | $10,000 | Not Implemented |
UD0395 # 01 Y:1993 | 01 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,009 | $2,080 | Implemented |
UD0395 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,051 | $8,096 | Implemented |
UD0395 # 03 Y:1993 | 03 | 1993 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,731 | $0 | Implemented |
UD0395 # 07 Y:1993 | 07 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,563 | $10,625 | Implemented |
UD0395 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,516 | $1,200 | Implemented |
UD0395 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,997 | $48,174 | Not Implemented |
SD0070 # 08 Y:1993 | 08 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,052 | $735 | Implemented |
SD0070 # 06 Y:1993 | 06 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $7,258 | $7,590 | Implemented |
SD0070 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,910 | $3,450 | Implemented |
SD0070 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,419 | $200 | Implemented |
SD0070 # 07 Y:1993 | 07 | 1993 | INSTALL SET-BACK TIMERS | $1,719 | $3,360 | Implemented |
SD0070 # 02 Y:1993 | 02 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,339 | $8,744 | Implemented |
SD0070 # 04 Y:1993 | 04 | 1993 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $6,505 | $15,000 | Implemented |
SD0070 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $680 | $1,041 | Implemented |
AR0015 # 05 Y:1993 | 05 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $18,409 | $5,000 | Not Implemented |
AR0015 # 06 Y:1993 | 06 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $25,253 | $12,000 | Not Implemented |
AR0015 # 04 Y:1993 | 04 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,187 | $14,712 | Not Implemented |
AR0015 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,562 | $1,000 | Implemented |
AR0015 # 02 Y:1993 | 02 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $14,046 | $6,750 | Not Implemented |
AR0015 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,666 | $740 | Not Implemented |
GT0514 # 03 Y:1993 | 03 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,450 | $900 | Implemented |
GT0514 # 02 Y:1993 | 02 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,010 | $7,520 | Implemented |
GT0514 # 04 Y:1993 | 04 | 1993 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,600 | $10,000 | Not Implemented |
GT0514 # 05 Y:1993 | 05 | 1993 | OPTIMIZE PLANT POWER FACTOR | $16,240 | $25,000 | Implemented |