IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

997

matching recommendations
Reset
SIC 341 Metal Cans And Shipping Containers
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0112 # 08 Y:1995 08 1995 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $208 $950 Implemented
UF0112 # 09 Y:1995 09 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $374 $520 Not Implemented
UF0112 # 10 Y:1995 10 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,129 $3,000 Implemented
UF0112 # 11 Y:1995 11 1995 OPTIMIZE PLANT POWER FACTOR $2,841 $12,951 Implemented
SD0107 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,588 $14,400 Implemented
SD0107 # 02 Y:1995 02 1995 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $94,795 $22,000 Implemented
SD0107 # 03 Y:1995 03 1995 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $9,603 $4,100 Not Implemented
SD0107 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $32,270 $62,889 Implemented
SD0107 # 05 Y:1995 05 1995 INSTALL SPECTRAL REFLECTORS / DELAMP $25,421 $23,285 Implemented
SD0107 # 06 Y:1995 06 1995 INSTALL OCCUPANCY SENSORS $2,466 $2,184 Implemented
SD0107 # 07 Y:1995 07 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $9,209 $1,260 Implemented
SD0107 # 08 Y:1995 08 1995 RECOVER AND REUSE COOLING WATER $8,450 $5,000 Not Implemented
SD0107 # 09 Y:1995 09 1995 RECOVER AND REUSE COOLING WATER $8,450 $4,885 Not Implemented
TN0537 # 01 Y:1995 01 1995 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $16,330 $2,190 Implemented
TN0537 # 02 Y:1995 02 1995 RECOVER WASTE HEAT FROM EQUIPMENT $2,348 $969 Not Implemented
TN0537 # 03 Y:1995 03 1995 INSULATE BARE EQUIPMENT $464 $950 Not Implemented
TN0537 # 04 Y:1995 04 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $827 $528 Not Implemented
TN0537 # 05 Y:1995 05 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $610 $780 Not Implemented
TN0537 # 06 Y:1995 06 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $740 $224 Implemented
DS0010 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $22,684 $46,994 Implemented
DS0010 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $1,474 $410 Implemented
DS0010 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,768 $12,485 Implemented
DS0010 # 04 Y:1994 04 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $5,560 $5,093 Implemented
DS0010 # 05 Y:1994 05 1994 USE RADIANT HEATER FOR SPOT HEATING $2,618 $15,600 Not Implemented
HO0085 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,495 $3,924 Implemented