Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
24
matching recommendationsSIC | 341 | Metal Cans And Shipping Containers |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0788 # 11 Y:2008 | 11 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $372 | $0 | Implemented |
UD0788 # 10 Y:2008 | 10 | 2008 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $590 | $0 | Implemented |
UD0788 # 09 Y:2008 | 09 | 2008 | UPGRADE CONTROLS ON COMPRESSORS | $1,037 | $200 | Implemented |
UD0788 # 08 Y:2008 | 08 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,134 | $7,000 | Not Implemented |
UD0788 # 07 Y:2008 | 07 | 2008 | INSTALL OCCUPANCY SENSORS | $2,123 | $3,500 | Implemented |
UD0788 # 06 Y:2008 | 06 | 2008 | AIR CONDITION ONLY SPACE NECESSARY | $13,860 | $0 | Implemented |
UD0788 # 05 Y:2008 | 05 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $17,084 | $0 | Not Implemented |
UD0788 # 04 Y:2008 | 04 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $20,385 | $440 | Implemented |
UD0788 # 03 Y:2008 | 03 | 2008 | OPTIMIZE PLANT POWER FACTOR | $26,537 | $21,250 | Implemented |
UD0788 # 02 Y:2008 | 02 | 2008 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $44,342 | $0 | Not Implemented |
UD0788 # 01 Y:2008 | 01 | 2008 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $49,954 | $12,500 | Implemented |
OR0529 # 04 Y:2008 | 04 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,767 | $4,515 | Not Implemented |
OR0529 # 03 Y:2008 | 03 | 2008 | CONTROL PRESSURE ON STEAMER OPERATIONS | $11,760 | $1,000 | Not Implemented |
OR0529 # 02 Y:2008 | 02 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,400 | $17,900 | Not Implemented |
OR0529 # 01 Y:2008 | 01 | 2008 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $8,800 | $4,900 | Not Implemented |
AM0545 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $68,500 | $45,600 | Implemented |
AM0545 # 09 Y:2008 | 09 | 2008 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,100 | $6,700 | Not Implemented |
AM0545 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,230 | $325 | Implemented |
AM0545 # 07 Y:2008 | 07 | 2008 | USE SYNTHETIC LUBRICANT | $2,870 | $0 | Implemented |
AM0545 # 06 Y:2008 | 06 | 2008 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,750 | $0 | Implemented |
AM0545 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,790 | $350 | Implemented |
AM0545 # 04 Y:2008 | 04 | 2008 | INSTALL SKYLIGHTS | $15,220 | $30,900 | Not Implemented |
AM0545 # 03 Y:2008 | 03 | 2008 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $178,620 | $5,000 | Implemented |
AM0545 # 02 Y:2008 | 02 | 2008 | ADOPT IN-HOUSE MATERIAL GENERATION | $29,390 | $77,000 | Implemented |