Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

132

matching recommendations
Reset
SIC 3421 Cutlery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
RU0090 # 06 Y:1990 06 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $176 $186 Not Implemented
RU0090 # 07 Y:1990 07 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,573 $500 Implemented
RU0090 # 08 Y:1990 08 1990 INSTALL / REPAIR INSULATION ON STEAM LINES $547 $15 Implemented
MA0134 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $556 $1,340 Implemented
MA0134 # 02 Y:1988 02 1988 INSTALL TIMERS AND/OR THERMOSTATS $3,972 $918 Implemented
MA0134 # 03 Y:1988 03 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $586 $0 Not Implemented
MA0134 # 04 Y:1988 04 1988 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $1,494 $1,085 Implemented
MA0134 # 05 Y:1988 05 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $274 $150 Not Implemented
MA0134 # 06 Y:1988 06 1988 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,334 $1,880 Not Implemented
CO0119 # 01 Y:1988 01 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $711 $500 Implemented
CO0119 # 02 Y:1988 02 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $683 $375 Implemented
CO0119 # 03 Y:1988 03 1988 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $889 $0 Implemented
CO0119 # 04 Y:1988 04 1988 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,270 $10,400 Not Implemented
CO0119 # 05 Y:1988 05 1988 INSTALL TIMERS AND/OR THERMOSTATS $2,794 $4,000 Not Implemented
CO0119 # 06 Y:1988 06 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $162 $349 Implemented
CO0119 # 07 Y:1988 07 1988 USE DEMAND CONTROLLER OR LOAD SHEDDER $4,867 $3,600 Implemented
CO0119 # 08 Y:1988 08 1988 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $5,514 $1,000 Not Implemented
CO0119 # 09 Y:1988 09 1988 INSTALL AUTOMATIC STACK DAMPER $677 $900 Not Implemented
CO0119 # 10 Y:1988 10 1988 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $487 $250 Implemented
MA0097 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $108 $86 Not Implemented
MA0097 # 02 Y:1987 02 1987 DE-ENERGIZE EXCESS TRANSFORMER CAPACITY $3,263 $12,000 Not Implemented
MA0097 # 03 Y:1987 03 1987 INSULATE BARE EQUIPMENT $922 $876 Not Implemented
MA0097 # 04 Y:1987 04 1987 INSULATE BARE EQUIPMENT $1,086 $851 Not Implemented
MA0097 # 05 Y:1987 05 1987 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,363 $5,500 Not Implemented
MA0097 # 06 Y:1987 06 1987 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $349 $2,167 Not Implemented