Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
21
matching recommendationsSIC | 3429 | Hardware, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0510 # 08 Y:2021 | 08 | 2021 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $690 | $40 | Not Implemented |
AS0510 # 07 Y:2021 | 07 | 2021 | UPGRADE CONTROLS ON COMPRESSORS | $713 | $3,359 | Implemented |
AS0510 # 06 Y:2021 | 06 | 2021 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,097 | $447 | Not Implemented |
AS0510 # 05 Y:2021 | 05 | 2021 | INSTALL HEAT PIPES / RAISE COOLING SETPOINT | $6,879 | $560 | Not Implemented |
AS0510 # 04 Y:2021 | 04 | 2021 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $7,800 | $453 | Not Implemented |
AS0510 # 03 Y:2021 | 03 | 2021 | INSTALL SPECTRAL REFLECTORS / DELAMP | $13,978 | $9,244 | Implemented |
AS0510 # 02 Y:2021 | 02 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,025 | $18,448 | Not Implemented |
AS0510 # 01 Y:2021 | 01 | 2021 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $18,281 | $200 | Not Implemented |
AS0193 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,904 | $6,140 | Not Implemented |
AS0193 # 08 Y:1996 | 08 | 1996 | REDUCE WATER USE WITH COUNTER CURRENT RINSING | $24,214 | $900 | Implemented |
AS0193 # 07 Y:1996 | 07 | 1996 | INSTALL OCCUPANCY SENSORS | $881 | $450 | Implemented |
AS0193 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,599 | $25,001 | Implemented |
AS0193 # 04 Y:1996 | 04 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,838 | $0 | Implemented |
AS0193 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $24,827 | $17,598 | Implemented |
AS0193 # 02 Y:1996 | 02 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,963 | $7,000 | Implemented |
AS0193 # 01 Y:1996 | 01 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $34,527 | $45,000 | Implemented |
AS0030 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $432 | $63 | Not Implemented |
AS0030 # 05 Y:1991 | 05 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $349 | $0 | Not Implemented |
AS0030 # 04 Y:1991 | 04 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $29 | $72 | Not Implemented |
AS0030 # 03 Y:1991 | 03 | 1991 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $3,235 | $2,000 | Not Implemented |
AS0030 # 02 Y:1991 | 02 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,895 | $500 | Not Implemented |