Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

26

matching recommendations
Reset
SIC 3429 Hardware, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0003 # 02 Y:2001 02 2001 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN $40,000 $15,120 Not Implemented
MI0003 # 03 Y:2001 03 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,044 $312 Implemented
MI0003 # 04 Y:2001 04 2001 METER WASTE WATER $25,076 $3,650 Not Implemented
MI0003 # 05 Y:2001 05 2001 $125,000 $136,000 Not Implemented
MI0003 # 06 Y:2001 06 2001 $40,000 $2,900 Implemented
MI0003 # 01 Y:2001 01 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,015 $10,000 Not Implemented
UF0202 # 12 Y:1998 12 1998 $4,615 $4,000 Not Implemented
UF0202 # 11 Y:1998 11 1998 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $73,408 $920 Not Implemented
UF0202 # 10 Y:1998 10 1998 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $12,020 $0 Not Implemented
UF0202 # 09 Y:1998 09 1998 USE ADSORPTION, ION EXCHANGE TO REMOVE CONTAMINANTS $157,194 $233,000 Not Implemented
UF0202 # 08 Y:1998 08 1998 MINIMIZE WATER USAGE $3,060 $3,300 Not Implemented
UF0202 # 07 Y:1998 07 1998 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $3,029 $10,283 Not Implemented
UF0202 # 06 Y:1998 06 1998 INSULATE BARE EQUIPMENT $24,336 $3,600 Not Implemented
UF0202 # 05 Y:1998 05 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $12,310 $1,200 Not Implemented
UF0202 # 04 Y:1998 04 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $10,241 $4,206 Not Implemented
UF0202 # 03 Y:1998 03 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,250 $42,433 Not Implemented
UF0202 # 02 Y:1998 02 1998 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,090 $200 Not Implemented
UF0202 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,736 $9,303 Not Implemented
UF0060 # 08 Y:1993 08 1993 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $1,618 $3,700 Not Implemented
UF0060 # 07 Y:1993 07 1993 OPTIMIZE PLANT POWER FACTOR $8,898 $13,975 Not Implemented
UF0060 # 06 Y:1993 06 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,268 $2,250 Not Implemented
UF0060 # 05 Y:1993 05 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,981 $9,710 Not Implemented
UF0060 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $281 $238 Not Implemented
UF0060 # 03 Y:1993 03 1993 INSTALL SPECTRAL REFLECTORS / DELAMP $11,130 $11,140 Not Implemented
UF0060 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $719 $2,833 Not Implemented