Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
32
matching recommendationsSIC | 343 | Plumbing And Heating, Except Electric |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MO0014 # 01 Y:1990 | 01 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,415 | $0 | Implemented |
MO0014 # 02 Y:1990 | 02 | 1990 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,339 | $0 | Implemented |
MO0014 # 03 Y:1990 | 03 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $119 | $212 | Implemented |
MO0014 # 04 Y:1990 | 04 | 1990 | INSULATE BARE EQUIPMENT | $434 | $792 | Implemented |
MO0014 # 06 Y:1990 | 06 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $472 | $650 | Implemented |
MO0014 # 07 Y:1990 | 07 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $351 | $450 | Implemented |
MO0014 # 05 Y:1990 | 05 | 1990 | INSULATE BARE EQUIPMENT | $434 | $792 | Implemented |
AM0099 # 14 Y:1990 | 14 | 1990 | INSTALL SET-BACK TIMERS | $170 | $135 | Not Implemented |
AM0099 # 01 Y:1990 | 01 | 1990 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $10,480 | $14,890 | Not Implemented |
AM0099 # 13 Y:1990 | 13 | 1990 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $250 | $500 | Implemented |
AM0099 # 12 Y:1990 | 12 | 1990 | INSTALL SET-BACK TIMERS | $739 | $52 | Implemented |
AM0099 # 11 Y:1990 | 11 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $750 | $1,060 | Not Implemented |
AM0099 # 10 Y:1990 | 10 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,416 | $400 | Implemented |
AM0099 # 09 Y:1990 | 09 | 1990 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,200 | $12,390 | Not Implemented |
AM0099 # 08 Y:1990 | 08 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,629 | $13,300 | Implemented |
AM0099 # 07 Y:1990 | 07 | 1990 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $3,800 | $15,200 | Not Implemented |
AM0099 # 06 Y:1990 | 06 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,180 | $1,200 | Implemented |
AM0099 # 05 Y:1990 | 05 | 1990 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,710 | $1,600 | Not Implemented |
AM0099 # 04 Y:1990 | 04 | 1990 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,330 | $3,000 | Implemented |
AM0099 # 03 Y:1990 | 03 | 1990 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $5,680 | $0 | Implemented |
AM0099 # 02 Y:1990 | 02 | 1990 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $7,860 | $5,600 | Not Implemented |
UD0317 # 01 Y:1990 | 01 | 1990 | MINIMIZE WATER USAGE | $4,564 | $4,200 | Implemented |
UD0317 # 02 Y:1990 | 02 | 1990 | REDESIGN PROCESS | $27,328 | $30,000 | Not Implemented |
UD0317 # 03 Y:1990 | 03 | 1990 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $19,080 | $70,000 | Not Implemented |
AM0079 # 06 Y:1990 | 06 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $340 | $0 | Implemented |