Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,546
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0174 # 02 Y:2008 | 02 | 2008 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $32,694 | $2,000 | Implemented |
MI0174 # 03 Y:2008 | 03 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $21,544 | $40 | Implemented |
MI0174 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,041 | $1,210 | Implemented |
MI0174 # 06 Y:2008 | 06 | 2008 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $4,075 | $322 | Implemented |
OK0768 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,704 | $17,980 | Implemented |
OK0768 # 12 Y:2008 | 12 | 2008 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $7,034 | $129,640 | Implemented |
OK0768 # 13 Y:2008 | 13 | 2008 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $25,952 | $64,800 | Implemented |
OK0768 # 14 Y:2008 | 14 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,760 | $7,525 | Implemented |
OK0768 # 15 Y:2008 | 15 | 2008 | IMPROVE COMBUSTION CONTROL CAPABILITY | $131,460 | $41,080 | Implemented |
MZ0022 # 01 Y:2008 | 01 | 2008 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $1,425 | $2,800 | Implemented |
MZ0022 # 02 Y:2008 | 02 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $382 | $900 | Implemented |
MZ0022 # 03 Y:2008 | 03 | 2008 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $11,853 | $5,458 | Implemented |
MZ0022 # 04 Y:2008 | 04 | 2008 | ELIMINATE/REDUCE AN OPERATION | $41,408 | $0 | Implemented |
NC0377 # 01 Y:2008 | 01 | 2008 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,484 | $2,800 | Implemented |
NC0377 # 02 Y:2008 | 02 | 2008 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,040 | $1,000 | Implemented |
NC0377 # 03 Y:2008 | 03 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $475 | $930 | Implemented |
NC0377 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $595 | $100 | Implemented |
NC0377 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,040 | $111,342 | Implemented |
NC0377 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,691 | $1,495 | Implemented |
AM0548 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $100,400 | $59,650 | Implemented |
AM0548 # 03 Y:2008 | 03 | 2008 | INSTALL SKYLIGHTS | $8,620 | $17,170 | Implemented |
AM0548 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,000 | $350 | Implemented |
AM0548 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,000 | $0 | Implemented |
AM0548 # 07 Y:2008 | 07 | 2008 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $620 | $0 | Implemented |
AM0548 # 08 Y:2008 | 08 | 2008 | USE SYNTHETIC LUBRICANT | $365 | $0 | Implemented |