Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,509
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0369 # 01 Y:1992 | 01 | 1992 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $14,242 | $0 | Not Implemented |
KU0369 # 02 Y:1992 | 02 | 1992 | USE RADIANT HEATER FOR SPOT HEATING | $10,390 | $38,850 | Not Implemented |
KU0369 # 03 Y:1992 | 03 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $1,781 | $430 | Implemented |
KU0369 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $466 | $1,769 | Not Implemented |
KU0369 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $366 | $0 | Not Implemented |
KU0369 # 06 Y:1992 | 06 | 1992 | INSTALL SET-BACK TIMERS | $918 | $750 | Not Implemented |
KU0369 # 07 Y:1992 | 07 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,856 | $125 | Implemented |
KU0369 # 08 Y:1992 | 08 | 1992 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,147 | $0 | Not Implemented |
UF0028 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $864 | $2,517 | Implemented |
UF0028 # 02 Y:1992 | 02 | 1992 | INSTALL SPECTRAL REFLECTORS / DELAMP | $6,437 | $2,400 | Implemented |
UF0028 # 03 Y:1992 | 03 | 1992 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $1,125 | $1,660 | Implemented |
UF0028 # 04 Y:1992 | 04 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,440 | $36,148 | Implemented |
RU0144 # 01 Y:1992 | 01 | 1992 | IMPROVE LUBRICATION PRACTICES | $743 | $800 | Not Implemented |
RU0144 # 02 Y:1992 | 02 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $572 | $66 | Implemented |
RU0144 # 03 Y:1992 | 03 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $640 | $479 | Implemented |
RU0144 # 04 Y:1992 | 04 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $754 | $4,750 | Not Implemented |
RU0144 # 05 Y:1992 | 05 | 1992 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,207 | $0 | Not Implemented |
RU0144 # 06 Y:1992 | 06 | 1992 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,917 | $2,520 | Not Implemented |
UF0021 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,886 | $7,727 | Not Implemented |
UF0021 # 02 Y:1992 | 02 | 1992 | INSTALL SPECTRAL REFLECTORS / DELAMP | $15,608 | $19,830 | Not Implemented |
UF0021 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $178 | $1,003 | Not Implemented |
UF0021 # 04 Y:1992 | 04 | 1992 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $494 | $1,320 | Not Implemented |
UF0021 # 05 Y:1992 | 05 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $276 | $3,841 | Not Implemented |
UF0021 # 06 Y:1992 | 06 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $261 | $200 | Not Implemented |
SD0006 # 01 Y:1991 | 01 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $490 | $605 | Not Implemented |