Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
152
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0229 # 01 Y:1995 | 01 | 1995 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $9,035 | $500 | Not Implemented |
WI0229 # 02 Y:1995 | 02 | 1995 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,344 | $1,400 | Implemented |
WI0229 # 03 Y:1995 | 03 | 1995 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $987 | $0 | Not Implemented |
WI0229 # 04 Y:1995 | 04 | 1995 | USE SYNTHETIC LUBRICANT | $500 | $0 | Not Implemented |
WI0229 # 05 Y:1995 | 05 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $228 | $0 | Implemented |
WI0197 # 01 Y:1994 | 01 | 1994 | UPGRADE OBSOLETE EQUIPMENT | $16,304 | $30,000 | Implemented |
WI0197 # 02 Y:1994 | 02 | 1994 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $33,894 | $500 | Implemented |
WI0197 # 03 Y:1994 | 03 | 1994 | INSULATE BARE EQUIPMENT | $6,277 | $1,167 | Not Implemented |
WI0197 # 04 Y:1994 | 04 | 1994 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,426 | $200 | Implemented |
WI0197 # 05 Y:1994 | 05 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,431 | $960 | Implemented |
WI0197 # 06 Y:1994 | 06 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,900 | $2,741 | Not Implemented |
WI0197 # 07 Y:1994 | 07 | 1994 | INSTALL OCCUPANCY SENSORS | $807 | $525 | Not Implemented |
WI0197 # 08 Y:1994 | 08 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $167 | $300 | Not Implemented |
WI0197 # 09 Y:1994 | 09 | 1994 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $404 | $0 | Not Implemented |
WI0062 # 01 Y:1989 | 01 | 1989 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $12,224 | $0 | Not Implemented |
WI0062 # 02 Y:1989 | 02 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $4,059 | $3,500 | Implemented |
WI0062 # 03 Y:1989 | 03 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $709 | $2,290 | Implemented |
WI0062 # 04 Y:1989 | 04 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,647 | $0 | Not Implemented |
WI0062 # 05 Y:1989 | 05 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,596 | $6,000 | Implemented |
WI0062 # 06 Y:1989 | 06 | 1989 | IMPROVE LUBRICATION PRACTICES | $1,320 | $0 | Not Implemented |
WI0062 # 07 Y:1989 | 07 | 1989 | INSTALL STORM WINDOWS AND DOORS | $959 | $2,090 | Not Implemented |
WI0032 # 01 Y:1988 | 01 | 1988 | IMPROVE LUBRICATION PRACTICES | $31,106 | $0 | Not Implemented |
WI0032 # 02 Y:1988 | 02 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,304 | $0 | Implemented |
WI0032 # 03 Y:1988 | 03 | 1988 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $912 | $0 | Implemented |
WI0032 # 04 Y:1988 | 04 | 1988 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,240 | $0 | Implemented |