Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,509
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0022 # 02 Y:2008 | 02 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $382 | $900 | Implemented |
MZ0022 # 03 Y:2008 | 03 | 2008 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $11,853 | $5,458 | Implemented |
MZ0022 # 04 Y:2008 | 04 | 2008 | ELIMINATE/REDUCE AN OPERATION | $41,408 | $0 | Implemented |
NC0377 # 01 Y:2008 | 01 | 2008 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,484 | $2,800 | Implemented |
NC0377 # 02 Y:2008 | 02 | 2008 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,040 | $1,000 | Implemented |
NC0377 # 03 Y:2008 | 03 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $475 | $930 | Implemented |
NC0377 # 04 Y:2008 | 04 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,415 | $11,000 | Not Implemented |
NC0377 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $595 | $100 | Implemented |
NC0377 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,040 | $111,342 | Implemented |
NC0377 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,691 | $1,495 | Implemented |
AM0548 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $100,400 | $59,650 | Implemented |
AM0548 # 02 Y:2008 | 02 | 2008 | OPTIMIZE PLANT POWER FACTOR | $12,300 | $17,275 | Not Implemented |
AM0548 # 03 Y:2008 | 03 | 2008 | INSTALL SKYLIGHTS | $8,620 | $17,170 | Implemented |
AM0548 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,000 | $350 | Implemented |
AM0548 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,000 | $0 | Implemented |
AM0548 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,085 | $620 | Not Implemented |
AM0548 # 07 Y:2008 | 07 | 2008 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $620 | $0 | Implemented |
AM0548 # 08 Y:2008 | 08 | 2008 | USE SYNTHETIC LUBRICANT | $365 | $0 | Implemented |
AM0548 # 09 Y:2008 | 09 | 2008 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $265 | $0 | Implemented |
OK0761 # 01 Y:2008 | 01 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,213 | $0 | Implemented |
OK0761 # 02 Y:2008 | 02 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,263 | $4,638 | Implemented |
OK0761 # 03 Y:2008 | 03 | 2008 | INSTALL OCCUPANCY SENSORS | $525 | $2,871 | Implemented |
OK0761 # 04 Y:2008 | 04 | 2008 | INSTALL SET-BACK TIMERS | $3,105 | $1,908 | Implemented |
OK0761 # 05 Y:2008 | 05 | 2008 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $5,200 | $0 | Implemented |
AM0546 # 01 Y:2008 | 01 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $33,360 | $17,050 | Not Implemented |