Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
26
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0184 # 01 Y:1993 | 01 | 1993 | OPTIMIZE PLANT POWER FACTOR | $13,967 | $31,500 | Not Implemented |
AM0184 # 02 Y:1993 | 02 | 1993 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,850 | $0 | Not Implemented |
AM0184 # 03 Y:1993 | 03 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,740 | $608 | Not Implemented |
AM0184 # 04 Y:1993 | 04 | 1993 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,314 | $2,511 | Not Implemented |
AM0184 # 05 Y:1993 | 05 | 1993 | USE SYNTHETIC LUBRICANT | $690 | $0 | Not Implemented |
AM0179 # 07 Y:1993 | 07 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $760 | $3,920 | Not Implemented |
AM0179 # 06 Y:1993 | 06 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,210 | $1,230 | Not Implemented |
AM0179 # 05 Y:1993 | 05 | 1993 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,640 | $0 | Not Implemented |
AM0179 # 04 Y:1993 | 04 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,280 | $500 | Implemented |
AM0179 # 03 Y:1993 | 03 | 1993 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,850 | $0 | Implemented |
AM0179 # 02 Y:1993 | 02 | 1993 | USE RADIANT HEATER FOR SPOT HEATING | $14,970 | $10,890 | Not Implemented |
AM0179 # 01 Y:1993 | 01 | 1993 | OPTIMIZE PLANT POWER FACTOR | $34,850 | $45,000 | Implemented |
AM0178 # 02 Y:1993 | 02 | 1993 | OPTIMIZE PLANT POWER FACTOR | $34,000 | $38,500 | Implemented |
AM0178 # 05 Y:1993 | 05 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,280 | $0 | Implemented |
AM0178 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,760 | $24,300 | Not Implemented |
AM0178 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,960 | $600 | Not Implemented |
AM0178 # 01 Y:1993 | 01 | 1993 | OPTIMIZE PLANT POWER FACTOR | $48,960 | $72,000 | Not Implemented |
AM0171 # 04 Y:1993 | 04 | 1993 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $18,500 | $72,675 | Not Implemented |
AM0171 # 05 Y:1993 | 05 | 1993 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,710 | $10,160 | Not Implemented |
AM0171 # 06 Y:1993 | 06 | 1993 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,100 | $0 | Implemented |
AM0171 # 07 Y:1993 | 07 | 1993 | REDESIGN PROCESS | $830 | $712 | Not Implemented |
AM0171 # 08 Y:1993 | 08 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,690 | $4,630 | Implemented |
AM0171 # 09 Y:1993 | 09 | 1993 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $520 | $0 | Implemented |
AM0171 # 03 Y:1993 | 03 | 1993 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $22,300 | $54,800 | Implemented |
AM0171 # 02 Y:1993 | 02 | 1993 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,780 | $10,160 | Not Implemented |