Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,112
matching recommendationsSIC | 3441 | Fabricated Structural Metal |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0236 # 04 Y:1999 | 04 | 1999 | INSTALL OCCUPANCY SENSORS | $455 | $200 | Not Implemented |
IA0236 # 05 Y:1999 | 05 | 1999 | RECYCLE CLEANING SOLVENT AND REUSE | $8,966 | $7,853 | Not Implemented |
KU0523 # 01 Y:1999 | 01 | 1999 | OPTIMIZE PLANT POWER FACTOR | $7,490 | $7,600 | Not Implemented |
KU0523 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,040 | $2,050 | Not Implemented |
KU0523 # 03 Y:1999 | 03 | 1999 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,100 | $560 | Not Implemented |
KU0523 # 04 Y:1999 | 04 | 1999 | USE SYNTHETIC LUBRICANT | $800 | $1,530 | Not Implemented |
KU0523 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $740 | $450 | Not Implemented |
KU0523 # 06 Y:1999 | 06 | 1999 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $4,740 | $6,300 | Not Implemented |
AS0253 # 01 Y:1999 | 01 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,900 | $4,824 | Not Implemented |
AS0253 # 02 Y:1999 | 02 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,416 | $160 | Not Implemented |
AS0253 # 03 Y:1999 | 03 | 1999 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,563 | $1,200 | Not Implemented |
AS0253 # 04 Y:1999 | 04 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $428 | $225 | Implemented |
AS0253 # 05 Y:1999 | 05 | 1999 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $468 | $560 | Implemented |
AS0253 # 06 Y:1999 | 06 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,296 | $60 | Not Implemented |
AS0253 # 07 Y:1999 | 07 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,611 | $1,060 | Implemented |
AS0253 # 08 Y:1999 | 08 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $780 | $60 | Implemented |
AS0253 # 09 Y:1999 | 09 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,737 | $270 | Not Implemented |
AS0249 # 01 Y:1999 | 01 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $351 | $375 | Not Implemented |
AS0249 # 02 Y:1999 | 02 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,404 | $120 | Not Implemented |
AS0249 # 03 Y:1999 | 03 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $641 | $2,625 | Not Implemented |
AS0249 # 04 Y:1999 | 04 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $213 | $792 | Implemented |
AS0249 # 05 Y:1999 | 05 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,775 | $90 | Not Implemented |
AS0249 # 06 Y:1999 | 06 | 1999 | ADOPT IN-HOUSE MATERIAL GENERATION | $6,187 | $90 | Implemented |
OK0540 # 01 Y:1998 | 01 | 1998 | MOVE PRODUCT USING MECHANICAL MEANS | $5,006 | $9,000 | n/a |
OK0540 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,180 | $2,828 | n/a |