Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,107
matching recommendationsSIC | 3441 | Fabricated Structural Metal |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0243 # 05 Y:1992 | 05 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $230 | $590 | Implemented |
CO0243 # 06 Y:1992 | 06 | 1992 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,380 | $5,600 | Implemented |
CO0243 # 07 Y:1992 | 07 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,540 | $16,210 | Implemented |
CO0243 # 08 Y:1992 | 08 | 1992 | USE MINIMUM SAFE OVEN VENTILATION | $260 | $680 | Implemented |
CO0243 # 09 Y:1992 | 09 | 1992 | INSULATE BARE EQUIPMENT | $610 | $3,410 | Implemented |
KU0369 # 01 Y:1992 | 01 | 1992 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $14,242 | $0 | Not Implemented |
KU0369 # 02 Y:1992 | 02 | 1992 | USE RADIANT HEATER FOR SPOT HEATING | $10,390 | $38,850 | Not Implemented |
KU0369 # 03 Y:1992 | 03 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $1,781 | $430 | Implemented |
KU0369 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $466 | $1,769 | Not Implemented |
KU0369 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $366 | $0 | Not Implemented |
KU0369 # 06 Y:1992 | 06 | 1992 | INSTALL SET-BACK TIMERS | $918 | $750 | Not Implemented |
KU0369 # 07 Y:1992 | 07 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,856 | $125 | Implemented |
KU0369 # 08 Y:1992 | 08 | 1992 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,147 | $0 | Not Implemented |
AS0035 # 01 Y:1991 | 01 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $495 | $698 | Implemented |
AS0035 # 02 Y:1991 | 02 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $265 | $0 | Implemented |
AS0035 # 03 Y:1991 | 03 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,203 | $1,000 | Implemented |
AS0035 # 04 Y:1991 | 04 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,320 | $40 | Implemented |
AS0035 # 05 Y:1991 | 05 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $641 | $75 | Implemented |
AS0035 # 06 Y:1991 | 06 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $164 | $324 | Implemented |
AM0125 # 01 Y:1991 | 01 | 1991 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $8,400 | $6,000 | Not Implemented |
AM0125 # 02 Y:1991 | 02 | 1991 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $9,000 | $12,500 | Not Implemented |
AM0125 # 03 Y:1991 | 03 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,970 | $1,450 | Not Implemented |
AM0125 # 04 Y:1991 | 04 | 1991 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,640 | $0 | Not Implemented |
AM0125 # 05 Y:1991 | 05 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,230 | $2,095 | Not Implemented |
AM0125 # 06 Y:1991 | 06 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $390 | $0 | Not Implemented |