Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

16

matching recommendations
Reset
SIC 3441 Fabricated Structural Metal
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0603 # 01 Y:1997 01 1997 $31,860 $12,660 Implemented
TN0603 # 02 Y:1997 02 1997 $31,200 $21,000 Implemented
TN0603 # 03 Y:1997 03 1997 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $30,580 $0 Not Implemented
TN0603 # 04 Y:1997 04 1997 USE AUTOMATIC CLEANING EQUIPMENT $18,020 $38,470 Not Implemented
TN0603 # 05 Y:1997 05 1997 USE RADIANT HEATER FOR SPOT HEATING $16,800 $19,100 Not Implemented
TN0603 # 06 Y:1997 06 1997 CONVERT TO AIR ASSISTED / AIRLESS PAINT GUNS $8,550 $13,100 Not Implemented
TN0603 # 07 Y:1997 07 1997 INSTALL TIMERS AND/OR THERMOSTATS $840 $140 Not Implemented
TN0603 # 08 Y:1997 08 1997 USE A RAG RECYCLE SERVICE $455 $0 Implemented
TN0603 # 09 Y:1997 09 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $120 $150 Implemented
TN0225 # 01 Y:1984 01 1984 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $5,090 $13,000 Not Implemented
TN0225 # 02 Y:1984 02 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,768 $95 Not Implemented
TN0225 # 03 Y:1984 03 1984 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $6,670 $0 Not Implemented
TN0225 # 04 Y:1984 04 1984 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,236 $500 Not Implemented
TN0225 # 05 Y:1984 05 1984 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN $18,012 $10,000 Not Implemented
TN0225 # 06 Y:1984 06 1984 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,056 $0 Not Implemented
TN0225 # 07 Y:1984 07 1984 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,159 $3,500 Not Implemented