Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
587
matching recommendationsSIC | 3443 | Fabricated Plate Work (boiler Shops) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0253 # 02 Y:1988 | 02 | 1988 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,357 | $0 | Implemented |
OK0253 # 05 Y:1988 | 05 | 1988 | USE RADIANT HEATER FOR SPOT HEATING | $4,721 | $13,000 | Implemented |
OK0253 # 06 Y:1988 | 06 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,613 | $0 | Implemented |
OK0253 # 08 Y:1988 | 08 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $44 | $88 | Implemented |
OK0243 # 02 Y:1988 | 02 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,185 | $0 | Implemented |
OK0243 # 03 Y:1988 | 03 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $101 | $150 | Implemented |
OK0243 # 05 Y:1988 | 05 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $133 | $227 | Implemented |
OK0243 # 06 Y:1988 | 06 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $68 | $0 | Implemented |
OK0247 # 01 Y:1988 | 01 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $147 | $400 | Implemented |
OK0247 # 03 Y:1988 | 03 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $574 | $0 | Implemented |
OK0247 # 04 Y:1988 | 04 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,222 | $645 | Implemented |
OK0247 # 05 Y:1988 | 05 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $332 | $142 | Implemented |
OK0247 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $212 | $447 | Implemented |
CO0108 # 01 Y:1987 | 01 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,311 | $300 | Implemented |
CO0108 # 02 Y:1987 | 02 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,480 | $1,300 | Implemented |
CO0108 # 03 Y:1987 | 03 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $4,532 | $1,050 | Implemented |
CO0108 # 04 Y:1987 | 04 | 1987 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,242 | $250 | Implemented |
CO0108 # 05 Y:1987 | 05 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $243 | $164 | Implemented |
GT0328 # 01 Y:1987 | 01 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $616 | $644 | Implemented |
GT0328 # 04 Y:1987 | 04 | 1987 | INSULATE BARE EQUIPMENT | $160 | $500 | Implemented |
GT0328 # 05 Y:1987 | 05 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,290 | $450 | Implemented |
GT0326 # 01 Y:1987 | 01 | 1987 | KEEP LAMPS AND REFLECTORS CLEAN | $1,390 | $1,577 | Implemented |
GT0326 # 02 Y:1987 | 02 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $92 | $40 | Implemented |
GT0326 # 03 Y:1987 | 03 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,700 | $1,050 | Implemented |
GT0326 # 06 Y:1987 | 06 | 1987 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $1,440 | $500 | Implemented |