Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
173
matching recommendationsSIC | 346 | Metal Forgings And Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0189 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $26,134 | $33,690 | Implemented |
ND0189 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,875 | $6,890 | Implemented |
ND0189 # 03 Y:1994 | 03 | 1994 | INSTALL OCCUPANCY SENSORS | $3,327 | $3,200 | Not Implemented |
ND0189 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $385 | $650 | Not Implemented |
ND0189 # 05 Y:1994 | 05 | 1994 | DISCONNECT BALLASTS | $346 | $955 | Implemented |
ND0189 # 06 Y:1994 | 06 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $10,653 | $500 | Not Implemented |
ND0189 # 07 Y:1994 | 07 | 1994 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,076 | $18,000 | Not Implemented |
ND0167 # 01 Y:1993 | 01 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,917 | $1,821 | n/a |
ND0167 # 02 Y:1993 | 02 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,686 | $200 | n/a |
ND0167 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $656 | $1,220 | n/a |
ND0167 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,118 | $225 | n/a |
ND0167 # 05 Y:1993 | 05 | 1993 | PAY UTILITY BILLS ON TIME | $1,136 | $0 | n/a |
ND0167 # 06 Y:1993 | 06 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $539 | $1,000 | n/a |
ND0167 # 07 Y:1993 | 07 | 1993 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $415 | $800 | n/a |
ND0167 # 08 Y:1993 | 08 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $260 | $0 | n/a |
ND0167 # 09 Y:1993 | 09 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $221 | $553 | n/a |
ND0167 # 10 Y:1993 | 10 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $100 | $382 | n/a |
ND0153 # 01 Y:1993 | 01 | 1993 | REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT | $48,899 | $0 | Not Implemented |
ND0153 # 02 Y:1993 | 02 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,413 | $6,235 | Implemented |
ND0153 # 03 Y:1993 | 03 | 1993 | USE UTILITY CONTROLLED POWER MANAGEMENT | $12,899 | $0 | Implemented |
ND0153 # 04 Y:1993 | 04 | 1993 | INSTALL / REPAIR INSULATION ON STEAM LINES | $12,527 | $1,413 | Not Implemented |
ND0153 # 05 Y:1993 | 05 | 1993 | OPTIMIZE PLANT POWER FACTOR | $11,871 | $16,760 | Implemented |
ND0153 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,992 | $1,262 | Implemented |
ND0153 # 07 Y:1993 | 07 | 1993 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $225 | $218 | Implemented |
ND0026 # 01 Y:1992 | 01 | 1992 | RECOVER AND REUSE COOLING WATER | $24,397 | $25,000 | Implemented |