Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
16
matching recommendationsSIC | 3462 | Iron And Steel Forgings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0130 # 01 Y:1988 | 01 | 1988 | RECOVER AND REUSE COOLING WATER | $4,097 | $12,000 | Implemented |
CO0130 # 02 Y:1988 | 02 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $406 | $0 | Implemented |
CO0130 # 03 Y:1988 | 03 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,197 | $200 | Implemented |
CO0130 # 04 Y:1988 | 04 | 1988 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,756 | $500 | Not Implemented |
CO0130 # 05 Y:1988 | 05 | 1988 | COVER OPEN TANKS | $1,520 | $300 | Implemented |
CO0130 # 06 Y:1988 | 06 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $744 | $200 | Implemented |
CO0130 # 07 Y:1988 | 07 | 1988 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $185 | $200 | Implemented |
CO0130 # 08 Y:1988 | 08 | 1988 | INSULATE BARE EQUIPMENT | $1,046 | $200 | Implemented |
CO0130 # 09 Y:1988 | 09 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,162 | $992 | Implemented |
CO0121 # 01 Y:1988 | 01 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,482 | $2,800 | Implemented |
CO0121 # 02 Y:1988 | 02 | 1988 | INCREASE AMOUNT OF CONDENSATE RETURNED | $896 | $200 | Not Implemented |
CO0121 # 03 Y:1988 | 03 | 1988 | INSULATE BARE EQUIPMENT | $321 | $700 | Not Implemented |
CO0121 # 04 Y:1988 | 04 | 1988 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,341 | $2,000 | Implemented |
CO0121 # 05 Y:1988 | 05 | 1988 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $567 | $500 | Implemented |
CO0121 # 06 Y:1988 | 06 | 1988 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,817 | $250 | Implemented |
CO0121 # 07 Y:1988 | 07 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,509 | $1,517 | Implemented |