IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,577

matching recommendations
Reset
SIC 347 Metal Services, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
RU0114 # 06 Y:1991 06 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,509 $500 Implemented
RU0114 # 07 Y:1991 07 1991 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $52,380 $15,000 Implemented
RU0114 # 08 Y:1991 08 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,442 $9,609 Implemented
CO0206 # 01 Y:1991 01 1991 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $900 $2,500 Not Implemented
CO0206 # 02 Y:1991 02 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $561 $157 Not Implemented
CO0206 # 03 Y:1991 03 1991 REDUCE VENTILATION AIR $891 $2,000 Not Implemented
CO0206 # 04 Y:1991 04 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $600 $1,000 Not Implemented
CO0206 # 05 Y:1991 05 1991 COVER OPEN TANKS $823 $580 Not Implemented
CO0206 # 06 Y:1991 06 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $580 $200 Not Implemented
CO0206 # 07 Y:1991 07 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $83 $242 Not Implemented
CO0206 # 08 Y:1991 08 1991 INSULATE BARE EQUIPMENT $226 $570 Not Implemented
AM0109 # 01 Y:1991 01 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,730 $400 Implemented
AM0109 # 02 Y:1991 02 1991 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $700 $156 Implemented
AM0109 # 03 Y:1991 03 1991 MODERATE COOLING TOWER OUTLET TEMPERATURE $550 $0 Implemented
AM0109 # 04 Y:1991 04 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $490 $294 Implemented
AM0109 # 05 Y:1991 05 1991 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $304 $0 Implemented
AM0109 # 06 Y:1991 06 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $32 $17 Implemented
MA0194 # 01 Y:1990 01 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $503 $79 Implemented
MA0194 # 02 Y:1990 02 1990 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $25,980 $38,667 Implemented
MA0194 # 03 Y:1990 03 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $96 $89 Implemented
MA0194 # 04 Y:1990 04 1990 INSULATE BARE EQUIPMENT $2,541 $7,188 Not Implemented
MA0194 # 05 Y:1990 05 1990 INSULATE BARE EQUIPMENT $520 $223 Implemented
MA0194 # 06 Y:1990 06 1990 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $2,174 $3,875 Not Implemented
MA0194 # 07 Y:1990 07 1990 HEAT WATER WITH EXHAUST HEAT $656 $494 Implemented
MA0186 # 01 Y:1990 01 1990 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,664 $5,000 Implemented