Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,577
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0317 # 08 Y:1987 | 08 | 1987 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $57 | $32 | Implemented |
UD0234 # 01 Y:1987 | 01 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,497 | $15,000 | Implemented |
UD0234 # 02 Y:1987 | 02 | 1987 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $1,021 | $0 | Implemented |
UD0234 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $200 | $60 | Implemented |
OK0218 # 01 Y:1987 | 01 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $291 | $255 | Implemented |
OK0218 # 02 Y:1987 | 02 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,933 | $1,500 | Implemented |
OK0218 # 03 Y:1987 | 03 | 1987 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,296 | $965 | Not Implemented |
OK0218 # 04 Y:1987 | 04 | 1987 | COVER OPEN TANKS | $7,769 | $3,608 | Not Implemented |
OK0218 # 05 Y:1987 | 05 | 1987 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $780 | $465 | Implemented |
OK0218 # 06 Y:1987 | 06 | 1987 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $1,136 | $503 | Implemented |
OK0218 # 07 Y:1987 | 07 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $25,085 | $52,000 | Not Implemented |
UD0222 # 01 Y:1987 | 01 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $50,976 | $0 | Implemented |
UD0222 # 02 Y:1987 | 02 | 1987 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $12,018 | $6,000 | Not Implemented |
UD0222 # 03 Y:1987 | 03 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,028 | $25,000 | Implemented |
UD0222 # 04 Y:1987 | 04 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $26,250 | $27,000 | Implemented |
UD0222 # 05 Y:1987 | 05 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,938 | $16,000 | Implemented |
MA0077 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $659 | $212 | Not Implemented |
MA0077 # 02 Y:1986 | 02 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $370 | $753 | Not Implemented |
MA0077 # 03 Y:1986 | 03 | 1986 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,888 | $4,650 | Not Implemented |
MA0077 # 04 Y:1986 | 04 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $11,705 | $7,200 | Not Implemented |
MA0077 # 05 Y:1986 | 05 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $17,850 | $22,500 | Not Implemented |
MA0077 # 06 Y:1986 | 06 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $580 | $40 | Not Implemented |
MA0077 # 07 Y:1986 | 07 | 1986 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $1,650 | $907 | Not Implemented |
MA0077 # 08 Y:1986 | 08 | 1986 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $5,082 | $0 | Not Implemented |
MA0063 # 03 Y:1986 | 03 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $428 | $586 | Implemented |