Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,577

matching recommendations
Reset
SIC 347 Metal Services, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0317 # 08 Y:1987 08 1987 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $57 $32 Implemented
UD0234 # 01 Y:1987 01 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,497 $15,000 Implemented
UD0234 # 02 Y:1987 02 1987 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,021 $0 Implemented
UD0234 # 03 Y:1987 03 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $200 $60 Implemented
OK0218 # 01 Y:1987 01 1987 INSTALL TIMERS AND/OR THERMOSTATS $291 $255 Implemented
OK0218 # 02 Y:1987 02 1987 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,933 $1,500 Implemented
OK0218 # 03 Y:1987 03 1987 INSTALL / REPAIR INSULATION ON STEAM LINES $1,296 $965 Not Implemented
OK0218 # 04 Y:1987 04 1987 COVER OPEN TANKS $7,769 $3,608 Not Implemented
OK0218 # 05 Y:1987 05 1987 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $780 $465 Implemented
OK0218 # 06 Y:1987 06 1987 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,136 $503 Implemented
OK0218 # 07 Y:1987 07 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $25,085 $52,000 Not Implemented
UD0222 # 01 Y:1987 01 1987 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $50,976 $0 Implemented
UD0222 # 02 Y:1987 02 1987 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $12,018 $6,000 Not Implemented
UD0222 # 03 Y:1987 03 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $28,028 $25,000 Implemented
UD0222 # 04 Y:1987 04 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $26,250 $27,000 Implemented
UD0222 # 05 Y:1987 05 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,938 $16,000 Implemented
MA0077 # 01 Y:1986 01 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $659 $212 Not Implemented
MA0077 # 02 Y:1986 02 1986 INSTALL / REPAIR INSULATION ON STEAM LINES $370 $753 Not Implemented
MA0077 # 03 Y:1986 03 1986 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $2,888 $4,650 Not Implemented
MA0077 # 04 Y:1986 04 1986 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $11,705 $7,200 Not Implemented
MA0077 # 05 Y:1986 05 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $17,850 $22,500 Not Implemented
MA0077 # 06 Y:1986 06 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $580 $40 Not Implemented
MA0077 # 07 Y:1986 07 1986 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY $1,650 $907 Not Implemented
MA0077 # 08 Y:1986 08 1986 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $5,082 $0 Not Implemented
MA0063 # 03 Y:1986 03 1986 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $428 $586 Implemented