Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
39
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0093 # 07 Y:2012 | 07 | 2012 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $360 | $20 | Not Implemented |
DL0093 # 06 Y:2012 | 06 | 2012 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $940 | $230 | Not Implemented |
DL0093 # 05 Y:2012 | 05 | 2012 | REDUCE VENTILATION AIR | $1,102 | $600 | Not Implemented |
DL0093 # 04 Y:2012 | 04 | 2012 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $1,680 | $5,000 | Not Implemented |
DL0093 # 03 Y:2012 | 03 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,360 | $50 | Not Implemented |
DL0093 # 01 Y:2012 | 01 | 2012 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $7,140 | $100 | Implemented |
RU0150 # 06 Y:1992 | 06 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,376 | $500 | Not Implemented |
RU0150 # 07 Y:1992 | 07 | 1992 | OPTIMIZE PLANT POWER FACTOR | $5,770 | $0 | Not Implemented |
RU0150 # 08 Y:1992 | 08 | 1992 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $123,105 | $327,000 | Not Implemented |
RU0150 # 05 Y:1992 | 05 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $517 | $30 | Not Implemented |
RU0150 # 04 Y:1992 | 04 | 1992 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $25,123 | $44,000 | Not Implemented |
RU0150 # 03 Y:1992 | 03 | 1992 | RECOVER AND REUSE COOLING WATER | $14,788 | $2,700 | Not Implemented |
RU0150 # 02 Y:1992 | 02 | 1992 | INSTALL EFFICIENT RECTIFIERS | $100,936 | $125,000 | Not Implemented |
RU0150 # 01 Y:1992 | 01 | 1992 | IMPROVE LUBRICATION PRACTICES | $4,940 | $2,000 | Not Implemented |