IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

94

matching recommendations
Reset
SIC 349 Misc. Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0435 # 05 Y:1991 05 1991 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $892 $190 Implemented
TN0435 # 04 Y:1991 04 1991 INSTALL SET-BACK TIMERS $1,932 $0 Implemented
TN0435 # 03 Y:1991 03 1991 KEEP LAMPS AND REFLECTORS CLEAN $2,939 $4,256 Implemented
TN0435 # 02 Y:1991 02 1991 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $2,926 $0 Implemented
TN0435 # 01 Y:1991 01 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,971 $6,000 Implemented
TN0435 # 08 Y:1991 08 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $338 $322 Implemented
ND0004 # 03 Y:1991 03 1991 DISCONNECT BALLASTS $25 $50 Implemented
ND0004 # 01 Y:1991 01 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $310 $615 Implemented
ND0004 # 02 Y:1991 02 1991 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,370 $160 Implemented
TN0435 # 07 Y:1991 07 1991 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $244 $410 Implemented
TN0435 # 06 Y:1991 06 1991 COVER OPEN TANKS $910 $315 Implemented
TN0435 # 09 Y:1991 09 1991 USE DEMAND CONTROLLER OR LOAD SHEDDER $3,305 $9,700 Implemented
UF0006 # 02 Y:1991 02 1991 INSTALL SET-BACK TIMERS $5,368 $0 Not Implemented
UF0006 # 01 Y:1991 01 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,976 $625 Not Implemented
UF0006 # 04 Y:1991 04 1991 INSTALL SPECTRAL REFLECTORS / DELAMP $12,654 $12,570 Not Implemented
WI0118 # 02 Y:1991 02 1991 INSTALL TIMERS AND/OR THERMOSTATS $11,458 $200 Implemented
WI0118 # 15 Y:1991 15 1991 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $361 $700 Implemented
UF0006 # 07 Y:1991 07 1991 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,148 $0 Not Implemented
WI0118 # 01 Y:1991 01 1991 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $22,344 $0 Implemented
UF0006 # 05 Y:1991 05 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $131 $245 Not Implemented
UF0006 # 06 Y:1991 06 1991 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $90 $88 Not Implemented
UF0006 # 03 Y:1991 03 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $728 $2,250 Not Implemented
OK0351 # 04 Y:1991 04 1991 INSTALL TIMERS AND/OR THERMOSTATS $458 $750 Not Implemented
OK0351 # 03 Y:1991 03 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,637 $0 Not Implemented
OK0351 # 02 Y:1991 02 1991 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $15,053 $0 Not Implemented