Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsSIC | 3494 | Valves And Pipe Fittings, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0267 # 06 Y:1985 | 06 | 1985 | AIR CONDITION ONLY SPACE NECESSARY | $1,860 | $1,000 | Implemented |
GT0267 # 05 Y:1985 | 05 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,968 | $3,547 | Not Implemented |
GT0267 # 04 Y:1985 | 04 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,640 | $450 | Implemented |
GT0267 # 03 Y:1985 | 03 | 1985 | COVER OPEN TANKS | $3,200 | $600 | Implemented |
GT0267 # 02 Y:1985 | 02 | 1985 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $1,200 | $16,250 | Not Implemented |
GT0267 # 01 Y:1985 | 01 | 1985 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,275 | $3,300 | Not Implemented |
TN0257 # 05 Y:1985 | 05 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,048 | $450 | Implemented |
TN0257 # 04 Y:1985 | 04 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,915 | $0 | Not Implemented |
TN0257 # 03 Y:1985 | 03 | 1985 | COVER OPEN TANKS | $3,102 | $200 | Not Implemented |
TN0257 # 02 Y:1985 | 02 | 1985 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $8,904 | $37,200 | Not Implemented |
TN0257 # 01 Y:1985 | 01 | 1985 | USE HEAT PUMP FOR SPACE CONDITIONING | $17,233 | $429,000 | Not Implemented |
GT0263 # 06 Y:1985 | 06 | 1985 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $21,300 | $400 | Implemented |
GT0263 # 05 Y:1985 | 05 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $787 | $3,679 | Implemented |
GT0263 # 04 Y:1985 | 04 | 1985 | COVER OPEN TANKS | $1,100 | $320 | Not Implemented |
GT0263 # 03 Y:1985 | 03 | 1985 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $1,500 | $3,000 | Not Implemented |
GT0263 # 02 Y:1985 | 02 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,934 | $75 | Not Implemented |
GT0263 # 01 Y:1985 | 01 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $58,700 | $82,000 | Implemented |
OK0160 # 01 Y:1985 | 01 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $622 | $100 | Implemented |
OK0160 # 02 Y:1985 | 02 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,464 | $300 | Implemented |
OK0160 # 03 Y:1985 | 03 | 1985 | USE RADIANT HEATER FOR SPOT HEATING | $2,869 | $5,000 | Not Implemented |
OK0160 # 04 Y:1985 | 04 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $386 | $500 | Not Implemented |
GT0249 # 04 Y:1985 | 04 | 1985 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $277 | $150 | Implemented |
GT0249 # 03 Y:1985 | 03 | 1985 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $218 | $585 | Not Implemented |
GT0249 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $940 | $277 | Implemented |
GT0249 # 01 Y:1985 | 01 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,317 | $500 | Implemented |