Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,117
matching recommendationsSIC | 3499 | Fabricated Metal Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0012 # 04 Y:1987 | 04 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,335 | $2,000 | Implemented |
WI0012 # 05 Y:1987 | 05 | 1987 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,508 | $5,000 | Not Implemented |
AT0057 # 01 Y:1986 | 01 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $355 | $250 | Not Implemented |
AT0057 # 02 Y:1986 | 02 | 1986 | IMPROVE LUBRICATION PRACTICES | $299 | $0 | Implemented |
AT0057 # 03 Y:1986 | 03 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $972 | $1,500 | Implemented |
AT0057 # 04 Y:1986 | 04 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $187 | $0 | Implemented |
AT0057 # 05 Y:1986 | 05 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $453 | $0 | Implemented |
AT0057 # 06 Y:1986 | 06 | 1986 | COVER OPEN TANKS | $5,222 | $300 | Not Implemented |
AT0057 # 07 Y:1986 | 07 | 1986 | INSULATE BARE EQUIPMENT | $1,261 | $250 | Not Implemented |
TN0263 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,113 | $11,950 | Implemented |
TN0263 # 02 Y:1985 | 02 | 1985 | INSTALL SET-BACK TIMERS | $1,776 | $0 | Not Implemented |
TN0263 # 03 Y:1985 | 03 | 1985 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $1,318 | $0 | Implemented |
ST0042 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,822 | $810 | Not Implemented |
ST0042 # 02 Y:1985 | 02 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,086 | $200 | Implemented |
ST0042 # 03 Y:1985 | 03 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $350 | $110 | Not Implemented |
ST0042 # 04 Y:1985 | 04 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,863 | $2,700 | Implemented |
ST0042 # 05 Y:1985 | 05 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $799 | $537 | Implemented |
ST0042 # 06 Y:1985 | 06 | 1985 | INSTALL AUTOMATIC STACK DAMPER | $1,762 | $1,640 | Not Implemented |
ST0042 # 07 Y:1985 | 07 | 1985 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $599 | $70 | Implemented |
ST0042 # 08 Y:1985 | 08 | 1985 | USE SOLAR HEAT TO HEAT WATER | $447 | $0 | Not Implemented |
ST0011 # 01 Y:1984 | 01 | 1984 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,259 | $0 | Implemented |
ST0011 # 02 Y:1984 | 02 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $148 | $537 | Not Implemented |
ST0011 # 03 Y:1984 | 03 | 1984 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $1,083 | $190 | Implemented |
ST0011 # 04 Y:1984 | 04 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,107 | $2,290 | Implemented |
ST0011 # 05 Y:1984 | 05 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $138 | $0 | Implemented |