Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
524
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0411 # 05 Y:2008 | 05 | 2008 | INSTALL OCCUPANCY SENSORS | $1,200 | $215 | Implemented |
UF0411 # 06 Y:2008 | 06 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $888 | $364 | Not Implemented |
UF0411 # 07 Y:2008 | 07 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $62,348 | $20,000 | Not Implemented |
UF0411 # 08 Y:2008 | 08 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,520 | $1,000 | Not Implemented |
UF0411 # 09 Y:2008 | 09 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $53,144 | $426 | Implemented |
UF0411 # 10 Y:2008 | 10 | 2008 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $10,946 | $25,280 | Not Implemented |
UF0411 # 11 Y:2008 | 11 | 2008 | MODIFY WORKLOAD | $8,002 | $0 | Not Implemented |
UF0411 # 12 Y:2008 | 12 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,419 | $3,400 | Not Implemented |
UF0411 # 13 Y:2008 | 13 | 2008 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $110,982 | $0 | Implemented |
MI0148 # 01 Y:2007 | 01 | 2007 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $8,264 | $915 | Not Implemented |
MI0148 # 02 Y:2007 | 02 | 2007 | DISCONNECT BALLASTS | $5,169 | $2,150 | Not Implemented |
MI0148 # 03 Y:2007 | 03 | 2007 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,272 | $10,200 | Not Implemented |
MI0148 # 04 Y:2007 | 04 | 2007 | INSTALL SKYLIGHTS | $5,197 | $16,736 | Not Implemented |
MI0148 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,440 | $1,074 | Not Implemented |
MI0148 # 06 Y:2007 | 06 | 2007 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,961 | $3,010 | Not Implemented |
MI0148 # 07 Y:2007 | 07 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,128 | $1,423 | Not Implemented |
MI0148 # 08 Y:2007 | 08 | 2007 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $452 | $160 | Not Implemented |
UF0390 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $148,376 | $619,757 | Not Implemented |
UF0390 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,981 | $8,763 | Not Implemented |
UF0390 # 03 Y:2006 | 03 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $87,992 | $39,000 | Not Implemented |
UF0390 # 04 Y:2006 | 04 | 2006 | AIR CONDITION ONLY SPACE NECESSARY | $41,661 | $1,080 | Not Implemented |
UF0390 # 05 Y:2006 | 05 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,722 | $0 | Not Implemented |
UF0390 # 06 Y:2006 | 06 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,951 | $31,040 | Not Implemented |
UF0390 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $29,826 | $513 | Not Implemented |
UF0390 # 08 Y:2006 | 08 | 2006 | USE PHOTOCELL CONTROLS | $909 | $306 | Not Implemented |