Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
310
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0234 # 04 Y:1984 | 04 | 1984 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $233 | $408 | Not Implemented |
TN0211 # 01 Y:1984 | 01 | 1984 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $890 | $0 | Not Implemented |
TN0211 # 02 Y:1984 | 02 | 1984 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,051 | $0 | Implemented |
TN0211 # 03 Y:1984 | 03 | 1984 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,366 | $2,753 | Implemented |
TN0203 # 01 Y:1984 | 01 | 1984 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $49,685 | $7,200 | Implemented |
TN0203 # 02 Y:1984 | 02 | 1984 | TURN OFF EQUIPMENT WHEN NOT IN USE | $21,920 | $0 | Not Implemented |
TN0203 # 03 Y:1984 | 03 | 1984 | ADJUST VENTS TO MINIMIZE ENERGY USE | $7,310 | $20,000 | Implemented |
TN0203 # 04 Y:1984 | 04 | 1984 | INSULATE BARE EQUIPMENT | $2,840 | $232 | Implemented |
TN0203 # 05 Y:1984 | 05 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,679 | $0 | Implemented |
TN0203 # 06 Y:1984 | 06 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $150 | $200 | Implemented |
TN0205 # 01 Y:1984 | 01 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,391 | $100,000 | Not Implemented |
TN0205 # 02 Y:1984 | 02 | 1984 | INSTALL AUTOMATIC STACK DAMPER | $1,147 | $620 | Not Implemented |
TN0205 # 03 Y:1984 | 03 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,190 | $0 | Not Implemented |
TN0205 # 04 Y:1984 | 04 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $624 | $210 | Not Implemented |
TN0205 # 05 Y:1984 | 05 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $404 | $0 | Not Implemented |
TN0178 # 01 Y:1983 | 01 | 1983 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,560 | $500 | Not Implemented |
TN0178 # 02 Y:1983 | 02 | 1983 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $586 | $500 | Not Implemented |
TN0178 # 03 Y:1983 | 03 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $3,070 | $0 | Not Implemented |
TN0171 # 01 Y:1983 | 01 | 1983 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $23,000 | $13,000 | Not Implemented |
TN0171 # 02 Y:1983 | 02 | 1983 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $5,000 | $0 | Not Implemented |
TN0171 # 03 Y:1983 | 03 | 1983 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,800 | $400 | Not Implemented |
TN0166 # 01 Y:1983 | 01 | 1983 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $3,800 | $21,000 | Not Implemented |
TN0166 # 02 Y:1983 | 02 | 1983 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $12,600 | $25,000 | Not Implemented |
TN0166 # 03 Y:1983 | 03 | 1983 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,450 | $10,000 | Not Implemented |
TN0160 # 01 Y:1982 | 01 | 1982 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,925 | $625 | Not Implemented |