Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15,265
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0149 # 09 Y:2015 | 09 | 2015 | DISCONNECT BALLASTS | $275 | $90 | Not Implemented |
TT0149 # 10 Y:2015 | 10 | 2015 | INSTALL OCCUPANCY SENSORS | $384 | $804 | Implemented |
TT0149 # 11 Y:2015 | 11 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $247 | $1,200 | Implemented |
OK0903 # 01 Y:2015 | 01 | 2015 | INSTALL SET-BACK TIMERS | $28,117 | $86 | Not Implemented |
OK0903 # 02 Y:2015 | 02 | 2015 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $96,611 | $20,611 | Implemented |
OK0903 # 03 Y:2015 | 03 | 2015 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $3,411 | $228 | Implemented |
OK0903 # 04 Y:2015 | 04 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,633 | $30,000 | Implemented |
OK0903 # 05 Y:2015 | 05 | 2015 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $407 | $1,125 | Not Implemented |
OK0903 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,717 | $11,876 | Not Implemented |
OK0903 # 07 Y:2015 | 07 | 2015 | INSTALL OCCUPANCY SENSORS | $2,170 | $8,887 | Not Implemented |
OK0903 # 08 Y:2015 | 08 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,490 | $2,440 | Not Implemented |
OK0903 # 09 Y:2015 | 09 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,183 | $950 | Implemented |
OK0903 # 10 Y:2015 | 10 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,904 | $10,062 | Implemented |
OK0903 # 11 Y:2015 | 11 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,427 | $2,112 | Not Implemented |
OK0903 # 12 Y:2015 | 12 | 2015 | INSULATE BARE EQUIPMENT | $195 | $240 | Not Implemented |
BS0047 # 01 Y:2015 | 01 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $536 | $15 | Implemented |
BS0047 # 02 Y:2015 | 02 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,127 | $32,541 | Not Implemented |
BS0047 # 03 Y:2015 | 03 | 2015 | INSTALL OCCUPANCY SENSORS | $1,021 | $495 | Not Implemented |
BS0047 # 04 Y:2015 | 04 | 2015 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $20,278 | $200 | Not Implemented |
BS0047 # 05 Y:2015 | 05 | 2015 | ADOPT IN-HOUSE MATERIAL GENERATION | $38,230 | $27,200 | Not Implemented |
BD0455 # 01 Y:2015 | 01 | 2015 | USE RADIANT HEATER FOR SPOT HEATING | $140,934 | $105,000 | Not Implemented |
BD0455 # 02 Y:2015 | 02 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $19,322 | $13,700 | Implemented |
BD0455 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,997 | $40,950 | Implemented |
BD0455 # 04 Y:2015 | 04 | 2015 | INSTALL TIMERS AND/OR THERMOSTATS | $11,689 | $17,188 | Not Implemented |
BD0455 # 05 Y:2015 | 05 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $7,295 | $25 | Implemented |